Operations Guide
931281I
CyberData Corporation
2. On the
Sensor
page, enter values for the parameters indicated in
.
Note
The question mark icon (
) in the following table shows which web page items will be defined
after the
Toggle Help
button is pressed
.
Table 2-21. Sensor Page Parameters
Web Page Item
Description
Sensor Settings
Sensor Normally Closed
Select the inactive state of the sensor. The sensor is also known
as the Sense Input on the device's terminal block.
Sensor Timeout (in seconds)
The time (in seconds) the device will wait before it performs an
action when the on-board door sensor is activated. The action(s)
performed are based on the configured Sensor Settings below.
Enter up to 5 digits.
Activate Relay
When selected, the device's on-board relay will be activated until
the on-board sensor is deactivated.
Play Audio Locally
When selected, the device will loop an audio file out of the
speaker until the sensor is deactivated.
Make call to extension
When selected, the device will call an extension when the on-
board door sensor is activated. Use the
field
below to specify the extension the device will call.
Dial Out Extension
Specify the extension the device will call when the on-board
sensor is activated. Enter up to 64 alphanumeric characters.
Dial Out ID
An additional Caller identification string added to outbound calls.
Enter up to 64 alphanumeric characters.
Play recorded audio
When selected, the device will call the
play an audio file to the phone answering the SIP call
(corresponds to
on the
page).
Repeat Sensor Message
The number of times to repeat the audio message through the
local speaker or to the remote endpoint. A value of 0 will repeat
the message while the sensor is active. Enter a value from 0-
65536.
Sensor Strobe Settings
Blink Strobe on Sensor
When selected, the Strobe will blink a scene when the sensor is
triggered.
Scene
Select desired scene (only one may be chosen).
ADA Compliant
Strobe will blink ON at the specified brightness for 150ms then
OFF for 350ms during the duration of the event.
Slow Fade
Strobe will increase in brightness from 0 to the specified
brightness and back to 0 over the course of about 3.5 seconds
during the duration of the event.
Fast Fade
Strobe will increase in brightness from 0 to the specified
brightness and back to 0 over the course of about 1.5 seconds
during the duration of the event.
Slow Blink
Strobe will blink ON at the specified brightness for one second
then OFF for one second during the duration of the event.
Summary of Contents for InformaCast Enabled 011406
Page 80: ...Operations Guide 931281I CyberData Corporation Figure 2 41 SSL Configuration Page ...
Page 81: ...Operations Guide 931281I CyberData Corporation Figure 2 42 SSL Configuration Page ...
Page 90: ...Operations Guide 931281I CyberData Corporation Figure 2 47 Audiofiles Page ...
Page 91: ...Operations Guide 931281I CyberData Corporation Figure 2 48 Audiofiles Page ...