Chapter 6
:
Replacing Components
132
SE 300™ Ultra Hardware Reference
Replacing the Panel Sensors
Two panel sensors are mounted on the middle conveyor section and one panel sensor is
mounted on each left and right conveyor section. A fifth, smaller sensor is mounted near the
motor on the right side of the center conveyor section.
Parts
8004227 Panel Sensor
8009281 Panel Sensor
➢
To replace the panel sensors
1. Remove the two mounting screws and nut plate on the panel sensor (see Figure 102).
2. Clip the cable ties to free the panel sensor cable from the conveyor.
3. Disconnect panel sensor cable and remove the panel sensor.
4. Attach new panel sensor to the mounting bracket and secure with two screws.
5. Connect panel sensor cable.
6. Secure the cable ties so that the cables do not drag during X- or Y-axis motion.
i
Note:
Take care not to move the panel sensor along the X-axis. Movement along the X-axis
will affect system calibration.
Summary of Contents for SE 300 Ultra
Page 1: ...SE 300 Ultra Hardware Reference ...
Page 9: ...CyberOptics Corporation 1 Safety Safety Guidelines 2 Safety and Conformity Labeling 4 ...
Page 18: ...Chapter 1 Safety 10 SE 300 Ultra Hardware Reference ...
Page 96: ...Chapter 4 Running an Inspection 88 SE 300 Ultra Hardware Reference ...
Page 160: ...Chapter 7 Warranty and Spare Parts 152 SE 300 Ultra Hardware Reference ...