CyberOptics Corporation
17
SE 300 Ultra Electronics Drawer
SE 300 Ultra Electronics Drawer
The electronics drawer in the SE 300 Ultra contains the components described in the following
table and shown in Figure 17.
Table 3.
Electronics Drawer Components
Component
Description
AC Distribution Board
Distributes AC power to the subsystems through fuses on
this board.
AC Filter
Provide uniform AC power to system components.
Cable Breakout Board
Provides interface for auto-width conveyor cabling.
Computer
Real-time (RT) – Pentium® 4-based microprocessor that
controls the mechanical system, interfaces with the sensor,
and computes measurement results.
Windows® – Pentium 4-based microprocessor that provides
the user interface.
The computer contains a CD-ROM R/W drive and two 3.5
inch disk drives. The computer provides parallel, serial,
USB, and network connections.
Conveyor Speed Control
Used to set the inbound (load) and outbound (unload)
conveyor speeds to match your line speed.
Digital Input/Output Modules and Rack
Provides isolation for digital I/O signals.
Distribution Board
Distributes logic signals to system components.
Fans
Cool the electronics in the system.
Pneumatic Solenoids
Controls air used to the lift and clamp assemblies.
Power Supplies
Provide power and auxiliary power to the sensor, relay
board, and monitor.
Relay Board
Contains safety circuit relays and provides general power
distribution.
X- and Y-Axis Motor Controllers
Provide signal amplification and control for the X- and Y-axis
motors.
Summary of Contents for SE 300 Ultra
Page 1: ...SE 300 Ultra Hardware Reference ...
Page 9: ...CyberOptics Corporation 1 Safety Safety Guidelines 2 Safety and Conformity Labeling 4 ...
Page 18: ...Chapter 1 Safety 10 SE 300 Ultra Hardware Reference ...
Page 96: ...Chapter 4 Running an Inspection 88 SE 300 Ultra Hardware Reference ...
Page 160: ...Chapter 7 Warranty and Spare Parts 152 SE 300 Ultra Hardware Reference ...