CyberOptics Corporation
59
Verifying System Accuracy
➢
To verify accuracy of your SE 300 Ultra system
1. Install the disk in the floppy disk drive in the SE 300 Ultra system.
2. Copy the file
cert_<serial #>
to the system hard drive (for example, drive D). This file
performs both high resolution and high speed inspections.
3. Open the Solder Paste Inspection application.
4. Open the cert file.
5. Click
to run the inspection. Place the certification tool on the conveyor as you would a
board.
6. Click
to open the Failure Report and monitor the feature level results.
If the inspection results appear in green in the Panel View and there are no failures in the
Failure Report, the SE 300 Ultra system is accurate within specification.
If any of the inspection results appear in red in the Panel View and there are failures in the
Failure Report, the SE 300 Ultra system is not measuring accurately. Call CyberOptics
Service and Support.
i
Note:
If you want to perform repeatability testing, please contact CyberOptics Service and
Support. We can provide you with the methodology we used to meet our specifications.