CyberOptics Corporation
107
Electronics Drawer Components
Replacing EMO Relays
Parts
8001778 K1 – XY Safety/EMO Relay
8001777 K2 – Brake/EMO Relay
8001777 K3 – Brake and Z Safety/EMO Relay
➢
To replace EMO relays
1. Locate the EMO relays on the Relay board (see Figure 76).
2. Remove the screw on the cover of EMO relays.
3. Remove the cover plate.
4. Gently pull the EMO relay from the through-hole connectors on the Relay board.
5. Insert the new EMO relay, lining up the pins on the EMO relay with the holes on the Relay
board. Press firmly into place.
6. Secure the cover plate with a screw. Do not over-tighten the screw.
Figure 76.
EMO Relays
Caution:
The Relay board contains components that can be damaged by static electricity. Use a
ground strap when handling the board to prevent damage to sensitive components
K2 – Brake
K3 – Brake and Z-safety
K1 – XY safety