CyberOptics Corporation
67
Main Electrical Panel
Replacing the Drive Belts
Use this procedure to replace the auto width drive belt and manual width drive belt. This
procedure can be performed with access to the left/right of the machine in production line. This
section shows the procedure performed when the machine is not in production line.
Parts
Autowidth Timing belt
Manual width drive belt
Required Tools
–
No. 3 Allen key
–
No. 2 Allen key
➢
To replace the autowidth drive belt
1. Turn off all electrical power to the system. For more information, refer to the section
2. Perform step 1–6 for removing the auto width motor. Refer to the section “
3. Loosen the three screws from the drive pulley of the Auto Width Adjust.
4. Remove the drive pulley of the Auto Width Adjust as shown.
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.
Screws