CyberOptics Corporation
67
Main Electrical Panel
➢
To set the belt tension
1. To get the initial belt tension for setting 22 mm on the belt, push the Idler with minimum
force slowly in the direction of the arrow shown in Figure 64. Stop pushing the idler when
the belt is starting to strengthen.
Figure 64.
Idler
2. Make a line marking by using the ruler in line with the slot nut.
Figure 65.
Slot nut
3. Place a ruler in line with the marking (initial marking from Figure 65), from the ruler
reading, measure the distance/length at 22 mm.
Figure 66.
Marking with ruler
4. Mark a line with the ruler as shown in Figure 66 and start to push the Idler forward until it
reaches the 22 mm marking and tighten the set screw at 6 kgf.
Figure 67.
Idler with Marking
Slot nut
Marking
Marking
Marking