CyberOptics Corporation
67
Main Electrical Panel
Replacing the Panel Lifter Cylinder and Inductive
Sensor
Use this procedure to replace the panel lifter cylinder and inductive sensor. This procedure can
be performed with access to the left/right of the machine in the production line. This section
shows the procedures performed when the machine is not in production line.
Parts
Panel Lifter Cylinder
Required Tools
–
No. 3 Allen Key
–
No. 4 Allen Key
–
Screwdriver (+)
➢
To replace the panel lifter cylinder and inductive sensor
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the cover.
3. Make sure all motion has stopped.
4. Remove the centre lifter plate.
5. Remove the four screws on the centre lifter plate by using Allen Key No. 5.
6. Use a 10 mm wrench to unlock the lock nut at the cylinder.
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.
Centre Lifter Plate