Chapter 3
:
Replacing Components and Preventive Maintenance
66
SE500
CP
Hardware Manual
Replacing Leveling Feet
➢
To replace leveling feet
1. Using a forklift, raise the SE500
CP
frame off the floor.
2. Remove the two M8 screws that secure the plate and foot assembly to the frame.
3. Replace the damaged leveling foot.
4. Reassemble the foot assembly onto the frame.
5. Repeat steps 1–4 as required to replace the other leveling feet.
6. Adjust the leveling feet as needed to align the SE500
CP
with the conveyors. For more
information, refer to the section “
Positioning / Leveling the SE500CP System
” on page 26 for
details.
Figure 99.
Leveling Foot
Locking nut
Adjustment nut
Summary of Contents for SE500CP
Page 1: ...SE500CP Hardware Manual ...
Page 6: ...Contents vi SE500CP Hardware Manual ...
Page 10: ...x SE500CP Hardware Manual ...
Page 170: ...Index 160 SE500CP Hardware Manual ...