Main Electrical Panel
Main Electrical Panel
This section contains procedures for maintenance and replacing the following electrical panel
components:
●
Servo Amplifiers
●
Conveyor Motors
●
Safety Relay and Contactor
●
Middleman PCB Assembly
●
Power Supplies
●
Circuit Breakers
●
Electrical Cables
●
Fuses
●
Air Regulators
➢
To replace DIN rail-mounted components
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the hood on the SE500
CP
.
3. Make sure all motion has stopped.
4. Gain access to the main electrical panel by removing two screws that secure the lower front
panel to the machine frame.
5. Identify the part to replace (see Figure 32 on page 56) and disconnect the wires from the
terminals.
6. If present, remove attaching screws from the component.
7. Insert a flat blade screwdriver underneath the component and press down on the tab to
release it from the rail.
Figure 31.
DIN Rail Mounting
8. Hook the component onto the upper edge of the DIN rail and press downward to latch it onto
the rail.
Warning:
To prevent the risk of injury, turn the AC main circuit breaker to OFF to shut down
all electrical power to the SE500
CP
before starting any replacement operations. For more
information, refer to the section “
Releasing from DIN rail
Latching onto DIN rail