background image

 

K01-0000897-00

 

 

 

 

A1500SP1 

User

’s Manual 

 

 

 

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product in Registration section at 

CyberPowerSystems.com/registration

. Registration certifies your product's warranty, confirms your ownership in the event of a product loss or 

theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership. 

 

 

 

 

 

(SAVE THESE INSTRUCTIONS) 

This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries. 

CAUTION!   

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants.   

(Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before servicing 

the batteries. There are no user serviceable parts inside except for the battery. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded.   

If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery.   

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, 

ANSI/NFPA 75. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit  over  current  protection  in 

accordance with the National Electric Code, ANSI/NFPA 70. 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient 

care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

 

Condensation from 

the aquarium can cause the unit to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit on any transportation such as 

airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out. 

 

 

 

INTRODUCTION 

Thank you for selecting a CyberPower Systems Uninterruptible Power Supply (UPS) product. This UPS is designed to provide unsurpassed power 

protection, operation and performance during the lifetime of the product. 
 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS (b) 

User’s manual (c) USB A+B type cable (d) Function Setup Guide 

 

OVERVIEW

 

The

 

A1500SP1 provides complete power protection from utility power that is not always 

consistent.   

The A1500SP1 features 1500 Joules of surge protection. 

The unit ensures consistent power to your sump pump and provides long lasting battery 

backup during power outages with maintenance free batteries.   
 

AUTOMATIC VOLTAGE REGULATOR

 

The

 

A1500SP1

 

stabilizes inconsistent utility power voltage to consistent and safe 110/120 volts without 

switching to battery backup power. This help to reserve the battery for when 

it’s needed most during a 

blackout. 
 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the   

battery

’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours.   

Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the 

UPS is turned on or off. 

2.  Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment.   

The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up. 

3.  Elevate the UPS at least 18 inches above the floor on a stable surface like a table or shelf.   

4.  Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

5.  With the UPS unit turned off and unplugged, connect your sump pump into the battery power supplied outlet closest to the top of the unit. This unit 

will work with sump pumps up to 

1

/

2

 HP in size. 

DO NOT plug any additional equipment into the UPS, as any additional power demands 

may overload and damage the UPS.   

6.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is protected by a fuse or circuit breaker 

and does not service equipment with large electrical demands (e.g. air conditioner, 

copier, etc…).     

The warranty prohibits the use of extension cords, outlet strips, and surge strips. 

7.  Press the power switch to turn the unit on. The Power On indicator light will illumin

ate and the unit will “beep”. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the 

UPS off and ensure that the sump pump is no large than

1

/

2

 

HP in size and that no other devices are plugged into 

the unit. Make sure the circuit breaker is depressed and then turn the UPS on. 

8.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

9.  To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three 

months to ensure battery life. 

 

 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.      Power Switch   

Used as the master on/off switch for equipment connected to the battery power supplied outlets. (Please refer to the Function Setup Guide 
for more information.) 

2.      Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.   

3.

     

LCD module display

 

The LCD display shows all the UPS information using icons and messages.    For more information please review the 

“Definitions for Illuminated 

LCD Indicators

” section below. 

4.    Display/Select Button 

The button can be used to select the LCD display contents including Input Voltage, and output Voltage. Short press the button to scroll down the 

function menu. Pressing the button for 3 seconds will keep the LCD display always on or turn the LCD display off while in AC/Utility power mode. 

(Please refer to the Function Setup Guide for more information.) 

5. 

Mute/Enter Button 

Holding the button for more than 3 seconds will silence the alarm. Short press the ENTER button to confirm the setting. After the setting has 
been confirmed, the LCD screen will stop flashing. (Please refer to the Function Setup Guide for more information.) 

6. 

Battery and Surge Protected Outlets 

The UPS has battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your sump 

pump during a power failure. 

(DO NOT plug any additional devices into the 

“Battery and Surge Protected Outlets”. The power demands 

of these devices may overload and damage the unit.)

 

7. 

Full-Time Surge Protection Outlets 

The UPS has surge suppression outlets. 

8. 

Circuit Breaker 

Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.   

9. 

Serial/USB Ports to PC 

The USB port allows connection and communication between the USB port on the computer and the UPS unit. 

10.  Communication Protection Ports 

Communication protection ports, bi-directional, will protect a 10/100/1000 Ethernet connection (RJ45).     

11.  Wiring Fault Indicator (red) 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If this is 

illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The UPS will not provide 

surge protection without being plugged into a grounded and properly wired wall outlet. 

12.  Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver. 

13.  Outlets Designed for AC Adapters 

The unit has two outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

REPLACING THE BATTERY 

Replacement of batteries located in an 

OPERATOR ACCESS AREA

.   

1. 

When replacing batteries, replace with the same number of the following battery: CyberPower / RB1290X2 for A1500SP1. 

2. 

CAUTION! 

  Risk of Energy Hazard, maximum 24V 9 Ampere-hour battery for A1500SP1. Before replacing batteries, remove conductive 

jewelry such as chains, wrist watches, and rings. High energy conducted through these materials could cause severe burns. 

3. 

CAUTION! 

  Do not dispose of batteries in a fire. The batteries may explode. 

4. 

CAUTION! 

  Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. 

5. 

CAUTION:

    A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when 

working on batteries: 

(1) Remove watches rings, or other metal objects.

 

 

(2) Use tools with insulated handles. 

CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO 

LOCAL REGULATIONS. 

BATTERY REPLACEMENT PROCEDURE: 

 

A1500SP1 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS on its side. 

4. 

Remove the front panel retaining screws located on the bottom of the UPS. 

5. 

Slide the battery compartment cover (front panel) completely off of the unit. 

6. 

Disconnect the battery wires from the batteries. 

7. 

Remove the batteries from the compartment. 

8. 

Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from both the upper and lower 

battery pack. Note:

 

Only use new batteries for replacement and both batteries should be replaced at the same time to ensure maximum life 

span.     

9. 

Put the batteries back into the compartment. 

10. 

Slide back the battery compartment cover and tighten the retaining screws. 

11. 

Recharge the UPS for 8-16 hours to fully charge the battery. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
1. 

INPUT voltage meter: 

This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed, through the use of 
automatic voltage regulation, to continuously correct output voltage to connected equipment to a safe 120 voltage output range. In the event of 
a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120 output voltage. 
The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.

 

2. 

OUTPUT voltage meter: 

This meter measures, in real time, the AC voltage that the UPS system is providing to the computer, such as normal line mode, AVR mode, 
and battery backup mode. (Note: The OUTPUT voltage meter shows the status of the battery backup outlets.) 

3. 

ESTIMATED RUN TIME: 

This displays the run time estimate of the UPS with current battery capacity and load. 

4. 

NORMAL icon: 

This icon appears when the UPS is working under normal conditions. 

5. 

BATTERY icon: 

During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is 
operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS

’s batteries 

are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system down. 

6. 

AVR (Automatic Voltage Regulation) icon: 

This icon appears whenever your UPS is automatically correcting low AC line voltage without using battery power. This is a normal, automatic 
operation of your UPS, and no action is required on your part. 

7. 

SILENT MODE icon: 

This icon appears whenever the UPS is in silent mode. 

8. 

OVER LOAD icon: 

This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug some of your 
equipment from the battery-supplied outlets until the icon turns off and the alarm stops. 

9. 

FAULT icon: 

This icon appears if there is a problem with the UPS, Contact CyberPower Systems at for further help and support. 

E01:

 

Charger Fault 

– Overcharge

 (Contact CyberPower Systems for support.) 

E02: Charger Fault 

– No Charge

 (Contact CyberPower Systems for support.) 

E11:

 

Battery Overvoltage

 (Contact CyberPower Systems for support.) 

E21:

 

Battery Output Short Fault

 (Turn on the UPS again.) 

E22:

 

Battery Mode or AC/Utility Power Mode Overload Fault

 (Unplug at least one piece of equipment from battery outlets and turn the UPS 

on again.) 

10. 

BATT. CAPACITY meter: 

This meter displays the approximate charge level (in 20% increments) of the UPS’s internal battery. During a blackout or severe brownout, the 
UPS switches to battery power, the BATTERY icon appears, and the charge level decreases. 

11. 

LOAD CAPACITY meter: 

This meter displays the approximate output load level (in 20% increments) of the UPS battery outlets. 

 

For more information about functions setup, please refer to the 

Function Setup Guide

 
 
 
 
 
 
 
 
 
 
 
 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

IMPORTANT SAFETY INSTRUCTIONS 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

PRODUCT REGISTRATION 

 

Plug in 

18.00 in

ches

Reviews: