background image

Thank you for purchasing a CyberPower product.  This UPS is designed to provide unsurpassed 

power protection, operation, and performance during the lifetime of the product. Please take a 

few minutes to register your product at: 

www.CyberPowerSystems.com/registration

.  

Registration certifies your product’s warranty, confirms your ownership in the event of a product 

loss or theft, and entitles you to free technical support. Register your product now to receive the 

benefits of CyberPower ownership.

CAUTION! 

 To prevent the risk of fire or  

electric shock, install in a temperature and 

humidity controlled indoor area free of  

conductive contaminants. (Please see  

specifications for acceptable temperature  

and humidity range.) 

CAUTION!

 To reduce the risk of electric shock, 

do not remove the cover except to service the 

battery. Turn off and unplug the unit before

servicing the batteries. There are no user ser-

viceable parts inside except for the battery.

CAUTION!

 Hazardous live parts inside can be 

energized by the battery even when the AC 

input power is disconnected.

CAUTION!

 The UPS must be connected to an 

AC power outlet with fuse or circuit breaker 

protection. Do not plug into an outlet that is 

not grounded. If you need to de-energize this 

equipment, turn off and unplug the unit.

CAUTION!

 To avoid electric shock, turn off the 

unit and unplug it from the AC power source 

before installing a computer component.

CAUTION!

 To reduce the risk of fire, connect 

only to a circuit provided with 20 amperes 

maximum branch circuit over current protec-

tion in accordance with the National Electric 

Code, ANSI/NFPA 70.

CAUTION!

 Not for use in a computer room as 

defined in the Standard for the Protection of 

Electronic Computer/Data Processing Equip-

ment, ANSI/NFPA 75.

CAUTION!

 Do not dispose of batteries in a fire. 

The batteries may explode.

CAUTION!

 Do not open or mutilate batteries. 

Released electrolyte is harmful to the skin and 

eyes. It may be toxic.

DO NOT USE FOR MEDICAL  

OR LIFE SUPPORT EQUIPMENT!

  

CyberPower Systems does not sell products 

for life support or medical applications. DO 

NOT use in any circumstance that would affect 

operation and safety of life support equip-

ment, any medical applications or patient care.

DO NOT USE WITH OR NEAR AQUARIUMS!

  

To reduce the risk of fire or electric shock, do 

not use with or near an aquarium. Condensa-

tion from the aquarium can cause the unit to 

short out.

DO NOT USE THE UPS  

ON ANY TRANSPORTATION!

  

To reduce the risk of fire or electric shock, do 

not use the unit on any transportation such 

as airplanes or ships. The effect of shock or 

vibration caused during transit and the damp 

environment can cause the unit to short out.

PRODUCT REGISTRATION

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions  

carefully during installation and operation of the unit. Read this manual thoroughly before  

attempting to unpack, install, or operate your UPS.

Summary of Contents for AVR CP850PFCLCD

Page 1: ...erPowerSystems com FEATURES 1 Power Switch 2 Power On Indicator 3 LCD Module Display 4 Down Display Button 5 Up Mute Button 6 Enter Setup Button 7 USB charging ports Except for CP850PFCLCD 8 Battery a...

Page 2: ...ng a computer component CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric C...

Page 3: ...re cor rected to safe levels AVR automatically increases low utility power to a consistent and safe output voltage DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugge...

Page 4: ...the equipment being attached for proper accessibility SYSTEM FUNCTION BLOCK DIAGRAM EMI Filter Surge Suppressor AVR Charger AC DC Battery Inverter Input Output Normal Mode Battery Mode Advanced Energy...

Page 5: ...p Guide 7 USB charging ports Except for CP850PFCLCD The USB Power ports Type A and Type C provide DC 5V 3 1A power output 8 Battery and Surge Protected Outlets The unit has 5 battery powered and surge...

Page 6: ...ACING THE BATTERY BATTERY REPLACEMENT PROCEDURE CP850PFCLCD CP1000PFCLCD 1 Turn off and unplug all connected equipment 2 Turn the UPS off and unplug it from the AC power source 3 Turn the UPS on its s...

Page 7: ...T This icon appears if there is a problem with the UPS Press the POWER button to turn off the UPS E01 Charger Fault Overcharge Contact CyberPower Systems for support E02 Charger Fault No Charge Contac...

Page 8: ...teries at cyberpowersystems com support Mechanical problem Contact CyberPower Systems at cyberpowersystems com support PowerPanel is inactive all icons are gray The USB cable is not connected Connect...

Page 9: ...e cycles Recommended Battery Sealed Maintenance Free Lead Acid Battery Safety Approvals UL1778 CSA C22 2 No 107 3 FCC DoC Class B TROUBLESHOOTING Problem Possible Cause Solution PowerPanel is inactive...

Page 10: ...d and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a res...