Page 1: ...Userˊs Manual BPSE240V75ART3U BPSE240V75ART3UOA CyberPower Systems Inc www cyberpower com K01 C000117 02 ...

Page 2: ...4 2 VERTICAL TOWER INSTALLATION 8 5 ELECTRICAL INSTALLATION 10 5 1 One Battery module with 240Vdc input of the Power module 10 5 2 Multiple Battery modules with 240Vdc input of the Power module 11 5 3 Two Battery modules with 240Vdc input of the Power module 13 5 4 Multiple Battery modules with 240Vdc input of the Power module 13 6 TECHNICAL SPECIFICATION 14 ...

Page 3: ...r serviceable parts inside Refer servicing to qualified service personnel CAUTION Non Isolated Battery Supply Risk of electric shock battery circuit is not isolated from AC power source hazardous voltage may exist between battery terminals and ground Test before touching CAUTION Wiring must be done by qualified personnel CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not u...

Page 4: ...ctor before any other cables are connected DO NOT INSTALL THE UNIT WHERE IT WOULD BE EXPOSED TO DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE SERVICING OF BATTERIES SHOULD BE PERFORMED OR SUPERVISED BY PERSONNEL KNOWLEDGE OF BATTERIES AND THE REQUIRED PRECAUTIONS KEEP UNAUTHORIZED PERSONNEL AWAY FROM BATTERIES ...

Page 5: ...3 2 UNPACKING Battery module User s manual Rackmount left rail Rackmount right rail Rackmount ears Stands 2PCS Flat head screws M4X8L Pan head screws M5X12L Screw hole dust Plastic washers Battery Cable ...

Page 6: ...R PANEL DESCRIPTION Front View Rear View Fuse Replaceable fuse is accessible from the rear panel It must be done by qualified personnel Output Connector Use this output connector to connect the Battery module and the Power module Battery input Terminal Block Use this input Terminal Block to daisy chain the next Battery module ...

Page 7: ...ty is especially important to growing organizations with changing needs that value having the option to position a UPS on a floor or in a rackmount system Please follow the instructions below for the respective mounting methods 4 1 RACKMOUNT INSTALLATION Step1 Rackmount ears installation a Attach the two rackmount ears to the UPS using the provided screws M4X8L 8pcs b Insert dust cover into the ra...

Page 8: ...ion 9 b Attach the rackmount rail to your rack with two M5X12L screws and two plastic washers at the front of the rack Located in position 1 position 6 Do not tighten the screws Adjust the rail size on the rail assembly of your rack Secure the rail to the rear of the rack with two M5X12L screws and two plastic washers Tighten all screws at the front and rear of the rail Once completed perform the ...

Page 9: ...ace with the front of the unit facing toward you Secure the UPS to your rack with four M5X12L screws at the front of the rack Located in position 2 position 8 b Once completed perform the same steps for Power module CAUTION The Battery module must be installed below the UPS ...

Page 10: ...ION Attach the base stands 1 Without Power module a Tighten the screws M5X12 4pcs of the base stands rackmount ears onto the bottom of the Battery module b Insert dust cover into the rackmount ear screw holes that are not being used ...

Page 11: ... stands 2 With Power module a Tighten the screws M5X12 4pcs of the base stands rackmount ears onto the bottom of the UPS and Battery module b Insert dust cover into the rackmount ear screw holes that are not being used ...

Page 12: ...afety regulations 5 1 One Battery module with 240Vdc input of the Power module a Loosen the screws to remove the Terminal Block Cover located on the rear panel of Power module b Connect the Battery Cable to the Power module and ensure the polarity is right c Loosen the screws to remove the Output Connector Cover of Battery module ...

Page 13: ...le Battery modules with 240Vdc input of the Power module a Loosen the screws to remove the Battery input Terminal Block Cover and Output Connector Cover of the 1 Battery module b Connect Battery Cable to Battery input Terminal Block of the 1 Battery module and ensure the polarity is right 1 Battery module ...

Page 14: ...tput Connector Cover of the 2 Battery module d Connect the 1 Battery module to the 2 Battery module e Connect the 1 Battery module to Power module Refer to above steps of chapter 5 1 Once completed retighten the Block Cover 2 Battery module ...

Page 15: ...le Battery modules with 240Vdc input of the Power module Please refer to the following diagram and the steps of Connection 2 Power module Battery Input 240Vdc 4 Battery module Input Terminal Block N N 1 Battery module Output Connector 1 Battery module Input Terminal Block 3 Battery module Output Connector 3 Battery module Input Terminal Block 2 Battery module Output Connector 2 Battery module Inpu...

Page 16: ...680 Weight kg 55 66 Environment Operating Temperature 0 C to 40 C Relative Humidity 0 to 90 Non condensing CyberPower Systems Inc www cyberpower com 6F No 32 Sec 1 Chenggong Rd Nangang District Taipei 115 Taiwan Entire contents copyright 2013 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel Business Edition and PowerPanel Perso...