3 4
Sensitivity
Low
Medium
High
Escape to
Function
Menu
Medium
If the connected equipment can
tolerate more power events
(Example: unstable power often
associated with stormy weather),
select Low Sensitivity. The UPS will
go to Battery Mode less often. If the
connected equipment is more
sensitive to power events, select
High Sensitivity. The UPS will go to
Battery Mode more often.
Low Battery Warning
5~8 mins
Escape to
Function
Menu
5 mins
The audible alarm will sound and
the “BATT.” icon will flash when the
remaining runtime is less than the
value selected.
Self Test
YES
Escape to
Function
Menu
No action
In Line Mode, if Yes is selected, the
UPS will perform a self test.
Event Reset
YES
Escape to
Function
Menu
No action
This meter records the number of
power outages.
If Yes is selected, the EVENT
counter will be cleared.
Note: Pressing both the DISPLAY
and SETUP Button in Status
Display can also clear the EVENT
counter.
Return to Default Settings
YES
Escape to
Function
Menu
No action
If Yes is selected, the UPS will be
restored to the factory default
settings.
Return to Status Display
- -
- -
Press the ENTER button to go back
to the status display.