CP1350/1500AVRLCD 

 

 

 

 

CP850/1000AVRLCD 

 
 
 
 

 

 

CP850AVRLCD/CP1000AVRLCD/CP1350AVRLCD/CP1500AVRLCD 

User’s Manual 

K01-0000002-02 

 

 

 

Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at 

www.cpsww.com/registration

Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical 

support. Register your product now to receive the benefits of CyberPower ownership.

 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To  reduce  the  risk  of  electric  shock,  do  not  remove  the  cover  except  to  service  the  battery.  Turn  off  and  unplug  the  unit  before 

servicing the batteries. There are no user serviceable parts inside except for the battery. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer 

component. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit over  current  protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or 

patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation 

from the aquarium can cause the unit to short out. 

DO NOT USE THE UPS ON ANY TRANSPORTATION!   

To reduce the risk of fire or electric shock, do not use the unit on any transportation 

such as airplanes or ships.

 

The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out. 

 

 
 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) User’s manual (c) USB A+B type cable 

*PowerPanel® Personal Edition software is available on our website. Please visit www.cpsww.com and go to the Software Section for 
free download.

 

 

OVERVIEW

 

The

 

UPS provides complete power protection from utility power that is not always consistent. The 

CP850/1000/1350/1500AVRLCD features 1080/1080/1500/1500 Joules of surge protection. The units 

provide long lasting battery backup during power outages with maintenance free batteries. The 

CP850/1000/1350/1500AVRLCD ensures consistent power to your computer system and includes software 

that will automatically save your open files and shutdown your computer system during a utility power loss. 
 

AUTOMATIC VOLTAGE REGULATOR

 

The CP850/1000/1350/1500AVRLCD stabilizes inconsistent utility power voltage to nominal levels that are safe for equipment. Inconsistent 

incoming utility power may be damaging to important data files and hardware, but with Automatic Voltage Regulation (AVR), damaging voltage 

levels are corrected to safe levels.    AVR automatically increases low utility power or decreases high utility power to a consistent and safe 

110/120 volts. 

 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

  Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (850VA/510W for CP850AVRLCD, , 

1000VA/600W for CP1000AVRLCD, 1350VA/810W for CP1350AVRLCD, 1500VA/900W for CP1500AVRLCD).    If the rated capacities of 

the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the 

circuit breaker to trip.     

2.

  There are many factors that can affect the amount of power that your computer system will require.    It 

is suggested that the load placed on the battery outlets not exceed 80% of the unit’s capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure 

the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 

hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, 

the battery will automatically charge whether the UPS is turned on or off. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor, and any other

 

peripherals requiring battery backup into the 

battery power supplied outlets. 

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large 

electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and damage 

the unit. 

3.  To protect a fax, phone or modem, connect a telephone cable or network cable from the wall jack outlet to the IN   

jack of the UPS. Connect a telephone cable or network cable from the OUT jack of the UPS to a fax machine,   

telephone, modem, or network devices. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, copier, etc…).    The warranty prohibits the use of extension cords, outlet strips, and surge strips. 

5.  Press the power switch to turn the unit on.    The Power On indicator light will illuminate and the unit will “beep”. 

If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

6.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

7.  To store the UPS for an extended period, cover it and store with the battery fully charged.    While in storage, recharge the battery every three 

months to ensure battery life. 

8.  Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

 

 
 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

Power Switch   

Used as the master on/off switch for equipment connected to the battery power supplied outlets. 

Power On Indicator 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.   

LCD module display 

High resolution and intelligent LCD display shows all the UPS information using icons and messages.    For more information please review 

the “Definitions for Illuminated LCD Indicators” section below. 

LCD Display Toggle/Selected Switch 

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage, and Estimated Run Time. The toggle 

frequency is set to one time per second. Holding the switch for more than two seconds while running on battery will silence the buzzer. 

Battery and Surge Protected Outlets 

The unit has

 

battery powered/surge suppression outlets for connected equipment to ensure temporary uninterrupted operation of your 

equipment during a power failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other 

large electrical devices into the “Battery and Surge Protected Outlets”. The power demands of these devices may overload and 

damage the unit.)

 

Full-Time Surge Protection Outlets 

The unit has surge suppression outlets. 

Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will 

not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, telephone line, network or Ethernet connection (RJ11/RJ45). 

Circuit Breaker 

Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.   

10  Serial/USB Ports to PC 

The ports allow connection and communication between the USB/DB-9 port on the computer and the UPS unit. Note: Only one of these two 

ports can be used to communicate with your computer at one time. 

11  Coax/Cable/DSS Surge Protection 

The Coax/Cable/DSS protection ports will protect any cable modem, CATV converter, or DSS receiver. 

12  Outlet Designed for AC Adapters 

The unit has one outlet spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets. 

13  Input Power Cord 

Connect the unit into an AC outlet. 

REPLACING THE BATTERY 

CAUTION!

 Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of 

personnel knowledgeable of batteries and their precautions. 

CAUTION!

 Use only the specified type of battery. See your dealer for replacement batteries. 

CAUTION!

 The battery may present a risk of electrical shock. Do not dispose of battery in a fire as it may explode. Follow all local ordinances 

regarding proper disposal of batteries. Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as required by most 

state laws. 

CAUTION!

 Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic. 

CAUTION! 

A battery can present a high risk of short circuit current and electrical shock. Take the following precautions before replacing the 

battery: 

1. 

Remove all watches, rings or other metal objects. 

2. 

Only use tools with insulated handles. 

3. 

Do not lay tools or metal parts on top of battery or any terminals. 

4. 

Wear rubber gloves and boots. 

5. 

Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 

CONTACT WITH GROUNDED 

BATTERYCAN RESULT IN ELECTRICAL SHOCK!

 

 

BATTERY REPLACEMENT PROCEDURE: 

1. 

Turn off and unplug all connected equipment. 

2. 

Turn the UPS off and unplug it from the AC power source. 

3. 

Turn the UPS upside down. 

4. 

Remove the retaining screw. 

5. 

Slide the battery compartment cover completely off of the unit. 

6. 

Remove the batteries from the compartment. 

7. 

Disconnect the battery wires from the batteries. 

8. 

Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same color connectors from the battery pack. 

9. 

Put the batteries back into the compartment. 

10. 

Slide back the battery compartment cover and tighten the retaining screws. 

11. 

Recharge the UPS for 8-16 hours to fully charge the battery. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMINDER:   

Batteries are considered 

HAZARDOUS WASTE

 and must be disposed of properly.    Most retailers that sell lead-acid batteries 

collect used batteries for recycling, as required by local regulations. 

 

 
 

 

Power ON 

 

Wiring Fault 

 

Alarm 

CONDITION 

On 

Off 

Off 

Normal 

On 

Off 

Beep twice   

every 30 seconds 

Utility Failure- 

The UPS is providing power to battery power-supplied 

outlets from its battery. 

On 

Off 

Rapid Beeping 

every 1/2 second 

Utility Failure-

 The UPS is providing battery power.    Rapid beeping 

indicates the unit will run out of power shortly. 

Off 

Off 

Constant tone 

Battery  Overload  -

  Occurs  when  connected  equipment  exceeds  the 

listed  capacity  of  the  UPS.    Turn  the  UPS  off,  unplug  at  least  one 

piece  of  equipment  from  battery  outlets,  wait  10  seconds,  reset  the 

circuit breaker and turn the unit on. 

On/Off 

On 

None 

Electrical Wiring Fault - 

This 

indicates a wiring problem with the 

AC  outlet

  such  as  bad  ground,  missing  ground,  or  reversed  wiring.   

Disconnect  all  electrical  equipment  from  the  outlet  and  have  an 

electrician check the outlet to insure proper wiring. 

 

 

1. 

INPUT voltage meter: 

This meter measures the AC voltage that the UPS 

system is receiving from the utility wall outlet. The 

UPS is designed, through the use of automatic 

voltage regulation, to continuously correct output 

voltage to connected equipment to a safe 110/120 

voltage output range. In the event of a complete 

power loss, severe brownout, or over-voltage, the 

UPS relies on its internal battery to supply 

consistent 110/120 output voltage. The INPUT 

voltage meter can be used as a diagnostic tool to 

identify poor-quality input power.

 

2. 

OUTPUT voltage meter: 

This meter measures, in real time, the AC voltage that the UPS system is providing to the computer, such as normal line mode, AVR mode, 

 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

IMPORTANT SAFETY WARNINGS 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

 

 

DEFINITIONS FOR ILLUMINATED LED INDICATORS 