background image

6

 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

 

 

INPUT voltage meter: 

This meter measures the AC voltage 

that the UPS system is receiving from the utility wall outlet. The 
UPS is designed, through the use of automatic voltage 
regulation, to continuously supply connected equipment with 
stable, 220/230 output voltage. In the event of a complete 
power loss, severe brownout, or over-voltage, the UPS relies 
on its internal battery to supply consistent 220/230 output 
voltage. The 
INPUT voltage meter can be used as a diagnostic tool to 
identify poor-quality input power. 

OUTPUT voltage meter: 

This meter measures the AC voltage 

that the UPS system is providing to the computer, such as 
normal line mode, AVR mode, and battery back up mode. 

Note: The OUTPUT voltage meter shows the status of the battery back up outlets. 

ESTIMATE RUN TIME: 

This displays the run time estimate of the UPS with the current 

battery capacity and load. 

NORMAL icon: 

This icon appears when the UPS is working under normal GreenPower Bypass 

conditions. 

BATTERY icon: 

During a severe brownout or blackout, this icon appears and an alarm sounds (two 

short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. During a 
prolonged brownout or blackout, the alarm will sound continuously (and the BATT.CAPACITY meter 
shows one 20% capacity segment shaded) to indicate the UPS’s batteries are nearly out of power. You 
should save files and turn off your equipment immediately. 

AVR (Automatic Voltage Regulator) icon: 

This icon appears whenever your UPS is automatically 

correcting low AC line voltage without using battery power. This is a normal, automatic operation of 
your UPS, and no action is required on your part. 

SILENT MODE icon: 

This icon appears whenever the UPS is in silent mode. The buzzer does not 

beep during silent mode until the battery reaches low capacity. 

OVER LOAD icon: 

This icon appears and an alarm sounds to indicate the battery-supplied outlets are 

overloaded. To clear the overload, unplug some of your equipment from the battery-supplied outlets 
until the icon turns off and the alarm stops. 

FAULT icon: 

This icon appears if there is a problem with the UPS. Contact CyberPower Systems at 

service@cyberpower-eu.com for further help and support. 

BATT. CAPACITY meter: 

This meter displays the approximate charge level (in 20% increments) of the 

UPS’s internal battery. During a blackout or severe brownout, the UPS switches to battery power, the 
BATTERY icon appears, and the charge level decreases. 

LOAD CAPACITY meter: 

This meter displays the approximate output load level (in 20% increments) of 

the UPS’s battery outlets. 

 

Summary of Contents for CP1350EAVRLCD

Page 1: ...K01 0000076 00 CP1350EAVRLCD CP1500EAVRLCD User s Manual...

Page 2: ...except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WIT...

Page 3: ...s are providing power free of surges and spikes LCD Module Display High resolution and intelligent LCD display shows all the UPS information with icons and messages For more information please check t...

Page 4: ...switch to turn the unit on The power on indicator light will illuminate and the unit will beep 7 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct...

Page 5: ...minals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SH...

Page 6: ...a prolonged brownout or blackout the alarm will sound continuously and the BATT CAPACITY meter shows one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power You should...

Page 7: ...work Phone Fax Modem Protection RJ11 RJ45 One In One Out Operating Temperature 32 F to 104 F 0 C to 40 C Physical Total of UPS outlets Schuko x 6 Backup x 3 Maximum Dimensions LxWxH 37 1 x 10 0 x 24 9...

Page 8: ...s about replacement batteries at service cyberpower eu com The UPS will not turn on Mechanical problem Contact CyberPower Systems at service cyberpower eu com The USB cable is not connected Connect th...

Reviews: