TECHNICAL SPECIFICATIONS 

 

Model 

 

CP1350EAVRLCD CP1500EAVRLCD 

Capacity  (VA) 

1350VA/810W 

1500VA/900W 

Input 

 

Input Voltage Range 

165VAC~265VAC 

Frequency Range 

50/60Hz (Auto Sensing) 

AVR Function 

Boost @ 200+/-10V 

Output 

 

On Battery Output 
Voltage 

/-10% 

On Battery Output 
Frequency 

50/60Hz +/-1% 

Transfer Time 

8ms Typical 

Overload Protection 

On Utility: Circuit Breaker, On Battery: Internal Current Limiting 

Surge Protection 

 

Lightning / Surge 
Protection 

Yes 

Network/ Phone/ Fax/ 
Modem Protection 

RJ11/RJ45 ( One In/ One Out ) 

Operating Temperature 

+32

°

F to 104

°

F ( 0

°

C to 40

°

C ) 

Physical 

 

Total # of UPS outlets 

Schuko x 6 ( Backup x 3 ) 

Maximum 
Dimensions(LxWxH) 

37.1 x 10.0 x 24.9cm 

Weight (kg) 

11.5kg 

12.1kg 

Battery 

 

Sealed Maintenance 
Free Lead Acid Battery 

12V / 8Ah x2 

12V / 8.5Ah x2 

Typical Recharge Time 

8 hours 

Charging Current(Max.) 

0.7A 

User Replaceable 

Yes 

Status Indicators 

Indicators 

Power On, LCD Display 

Audible Alarms 

On Battery, Low Battery, Overload 

Communication 

 

PowerPanel

®

 Personal 

Edition Software 

Windows Vista/XP/2000/Server 2003, Linux 

Management 

 

Self -Test 

Yes 

Auto-Charger Yes 
Auto-Restart Yes 
USB interface 

Yes 

 

Summary of Contents for CP1350EAVRLCD

Page 1: ...K01 0000076 00 CP1350EAVRLCD CP1500EAVRLCD User s Manual...

Page 2: ...except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WIT...

Page 3: ...s are providing power free of surges and spikes LCD Module Display High resolution and intelligent LCD display shows all the UPS information with icons and messages For more information please check t...

Page 4: ...switch to turn the unit on The power on indicator light will illuminate and the unit will beep 7 If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct...

Page 5: ...minals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SH...

Page 6: ...a prolonged brownout or blackout the alarm will sound continuously and the BATT CAPACITY meter shows one 20 capacity segment shaded to indicate the UPS s batteries are nearly out of power You should...

Page 7: ...work Phone Fax Modem Protection RJ11 RJ45 One In One Out Operating Temperature 32 F to 104 F 0 C to 40 C Physical Total of UPS outlets Schuko x 6 Backup x 3 Maximum Dimensions LxWxH 37 1 x 10 0 x 24 9...

Page 8: ...s about replacement batteries at service cyberpower eu com The UPS will not turn on Mechanical problem Contact CyberPower Systems at service cyberpower eu com The USB cable is not connected Connect th...