 CPS725SL 

Guaranteed Uninterruptible Power System 

 

SPECIFICATIONS 

 

 

CPS725SL 

Capacity 

725VA(400W) 

Input Voltage on Utility 

100V to 140V 

Input Frequency 

57 Hz to 63 Hz 

On-Battery Output 
Voltage 

120Vac ± 5% 

Transfer Time 

4ms Typical 

Max. Load for UPS 
Outlets (3 Outlets) 

725VA(400W) 

Max. Load for Full-Time 
Surge Protection outlets 
(6 Outlets) 

 

12 Amps 

On-Battery Output Wave 
Form 

Simulated Sine Wave Form 

Operating Temperature 

+ 32°F to 95° F. (0° C to 35° C) 

Operating Relative 
Humidity 

0 to 95% NON-CONDENSING 

Size (Length x Width x 
Height) 

9 7/8” x 6 3/16” x 3 1/8” (25.8cm x 15.9cm x 8.3cm) 

Net Weight 

15 lbs. 

Typical Battery Re-
charge Time 

8 hours typical from total discharge 

Typical Battery Life 

3 to 6 years, depending on number of discharge/recharge cycles 

Battery Type 

12V / 9.0AH 

Recommended Battery 

Spill-proof, Maintenance-free, sealed lead-acid 

Safety Approvals 

UL1778(UPS), CUL107.1/FCC/DoC Class B 

 

EXPECTED RUNTIME IN MINUTES 

 

 CPS725SL 

Desktop PC with LCD Monitor 

42-65 

Desktop PC with 15” Monitor 

31-45 

Desktop PC with 17” Monitor 

23-34 

Desktop PC with 21” Monitor 

20-28 

 

Summary of Contents for CPS725SL

Page 1: ...User s Manual for CPS725SL with USB Interface and PowerPanel Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com FAQs htm...

Page 2: ...operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying PowerPanel software saves data closes open applicatio...

Page 3: ...nsures temporary uninterrupted operation of your equipment during a power failure 2 Full Time Surge Protection Outlets Provides three always on surge suppression outlets 3 Power Switch Can be used as...

Page 4: ...lied outlets Plug your peripheral equipment printer scanner speakers into the full time surge protection outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device...

Page 5: ...was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and start your computer 4 Once the computer was finished booting insert the PowerPanel disk into the floppy drive 5 Click on...

Page 6: ...tton to open the Scheduled Shutdown Window 6 AC Power Indicator This indicator appears in a green color when AC power in normal When the power fails the indicator will change to a red color with an X...

Page 7: ...utton to add the item to the schedule Please note The use of the schedule is optional and will have no effect on the shutdown of your system during a power failure This feature is simply used if you w...

Page 8: ...lure 3 The UPS will begin beeping indicating a power failure 4 Save and close any open files 5 Shut down the operating system 6 Once the computer system is shutdown turn the UPS off As the battery dis...

Page 9: ...he UPS is providing power to battery power supplied outlets from its battery Off On Off Set Rapid Beeps Utility Failure The UPS is providing battery power Rapid beeps indicate the unit will run out of...

Page 10: ...e battery is worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com The UPS will not turn on Mechanical problem Contact CyberPower Systems at tech cyberpowersyst...

Page 11: ...F 0 C to 35 C Operating Relative Humidity 0 to 95 NON CONDENSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 25 8cm x 15 9cm x 8 3cm Net Weight 15 lbs Typical Battery Re charge Time 8 hours t...

Page 12: ...by and become a party to the Limited Warranty and Power Control Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Power Control Guar antee you should return the Pr...

Page 13: ...rage whether or not the Initial Customer makes a claim for recovery includ ing but not limited to a claim under any applicable insurance other warranty or extended warranty The Limited Warranty does n...

Page 14: ...Agreed Damage Amount for all items of Initial Customer s Connected Equipment shall be the lesser of the amount determined under Clause 1 or 2 below reduced by any amounts described in Clause 3 below 1...

Page 15: ...ibed as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Eq...

Page 16: ...s 5555 12th Ave East Suite 110 Shakopee MN 55379 and its phone number is 952 403 9500 or 877 297 6937 toll free CyberPower is the warrantor under this Limited Warranty You may also contact CyberPower...

Page 17: ...uipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compli...

Reviews: