 CPS725SL 

Guaranteed Uninterruptible Power System 

 

IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS)

 

This manual contains important safety instructions. 

 

Please read and follow all instructions carefully during 
installation and operation of unit.  Read this manual 
thoroughly before attempting to unpack, install, or oper-
ate. 

CAUTION!

   

To prevent the risk of fire or electric shock, 

install in a temperature and humidity controlled indoor 
area, free of conductive contaminants.  (Please see 
specifications for acceptable temperature and humidity 
range). 

CAUTION!

   

To reduce the risk of electric shock, do not 

remove the cover except to service the battery.  No user 
serviceable parts inside except for battery. 

CAUTION!

  

Hazardous live parts inside can be energized 

by the battery even when the AC input power is discon-
nected. 

CAUTION!

   

UPS must be connected to an AC power 

outlet with fuse or circuit breaker protection.  Do not plug 
into an outlet that is not grounded.  If you need to de-
energize this equipment, turn off and unplug the unit. 

CAUTION!

  

To avoid electrical shock, turn off the unit and 

unplug it from the AC power source before servicing the 
battery or installing a computer component. 

DO NOT USE FOR MEDICAL OR LIFE SUPPORT 
EQUIPMENT!

   

CyberPower Systems does not sell prod-

ucts for life support or medical applications.  

DO NOT

 use 

in any circumstance that would affect operation or safety 
of any life support equipment or with any medical applica-
tions or patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!

   

To re-

duce the risk of fire or electric shock, do not use with or 
near an aquarium.

   

Condensation from the aquarium can 

cause the unit to short out. 

 
DESCRIPTION 

 

 

1.Battery/Surge Outlets 

Provides three battery powered/surge outlets for con-
nected equipment and insures temporary uninterrupted 
operation of your equipment during a power failure. 

2.Full-Time Surge Protection Outlets 

Provides three always on surge suppression outlets. 

3.Power Switch 

Can be used as a mater on/off switch for equipment 
connected to the battery power supplied outlets. 

4.Power On Indicator 

This LED is illuminated when the utility condition is normal 
and the UPS outlets are providing power, free of surges 
and spikes. 
 

5.Electrical Wiring Fault Indicator 

This LED indicator will illuminate to warn the user that a 
wiring problem exists, such as bad ground, miss ground 
or reversed wiring.  If this is illuminated, user is advised to 
disconnect all electrical equipment from the outlet and 
have an electrician check to ensure the outlet is properly 
wired. 

6.Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves 
to provide overload and fault protection.  Under normal 
operating conditions, the circuit breaker is depressed. 

7.Serial Port to PC 

This port allows connection and communication from the 
DB-9 serial port on the computer to the UPS unit.  The 
UPS communicates its status to the PowerPanel™ soft-
ware.  This interface is also compatible with the UPS 
service provided by Windows NT and Windows 2000. 

8.Coaxial Cable Surge Protection 

Connect the coaxial cable from your cable / antenna dish 
source to one of the surge protector’s video connectors 
market “IN”.  With another section of coaxial cable, con-
nect the surge protector’s corresponding video connector 
marked 

9.Communication Protection Ports 

Communication protection ports will protect any standard 
modem, fax or telephone line. 

10.Outlets Designed for AC Adapters 

Allows six AC power adapter blocks to be plugged into the 
UPS without blocking adjacent outlets. 

 

INSPECTION 

The box should contain the following: 

(1) PowerPanel™ software (floppy disk); (1) serial interface cable (DB-9);  
(1) telephone communication cable; (1) user manual; (1) warranty registration card; 
(1) USB adapter ; (1) UPS unit. 
 
 
 
 
 
 

Summary of Contents for CPS725SL

Page 1: ...User s Manual for CPS725SL with USB Interface and PowerPanel Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com FAQs htm...

Page 2: ...operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying PowerPanel software saves data closes open applicatio...

Page 3: ...nsures temporary uninterrupted operation of your equipment during a power failure 2 Full Time Surge Protection Outlets Provides three always on surge suppression outlets 3 Power Switch Can be used as...

Page 4: ...lied outlets Plug your peripheral equipment printer scanner speakers into the full time surge protection outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device...

Page 5: ...was supplied with the unit 3 Plug the UPS into an AC outlet turn the UPS on and start your computer 4 Once the computer was finished booting insert the PowerPanel disk into the floppy drive 5 Click on...

Page 6: ...tton to open the Scheduled Shutdown Window 6 AC Power Indicator This indicator appears in a green color when AC power in normal When the power fails the indicator will change to a red color with an X...

Page 7: ...utton to add the item to the schedule Please note The use of the schedule is optional and will have no effect on the shutdown of your system during a power failure This feature is simply used if you w...

Page 8: ...lure 3 The UPS will begin beeping indicating a power failure 4 Save and close any open files 5 Shut down the operating system 6 Once the computer system is shutdown turn the UPS off As the battery dis...

Page 9: ...he UPS is providing power to battery power supplied outlets from its battery Off On Off Set Rapid Beeps Utility Failure The UPS is providing battery power Rapid beeps indicate the unit will run out of...

Page 10: ...e battery is worn out Contact CyberPower Systems about replacement batteries at tech cyberpowersystems com The UPS will not turn on Mechanical problem Contact CyberPower Systems at tech cyberpowersyst...

Page 11: ...F 0 C to 35 C Operating Relative Humidity 0 to 95 NON CONDENSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 25 8cm x 15 9cm x 8 3cm Net Weight 15 lbs Typical Battery Re charge Time 8 hours t...

Page 12: ...by and become a party to the Limited Warranty and Power Control Guarantee If you do not agree to the terms and conditions of the Limited Warranty and Power Control Guar antee you should return the Pr...

Page 13: ...rage whether or not the Initial Customer makes a claim for recovery includ ing but not limited to a claim under any applicable insurance other warranty or extended warranty The Limited Warranty does n...

Page 14: ...Agreed Damage Amount for all items of Initial Customer s Connected Equipment shall be the lesser of the amount determined under Clause 1 or 2 below reduced by any amounts described in Clause 3 below 1...

Page 15: ...ibed as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Eq...

Page 16: ...s 5555 12th Ave East Suite 110 Shakopee MN 55379 and its phone number is 952 403 9500 or 877 297 6937 toll free CyberPower is the warrantor under this Limited Warranty You may also contact CyberPower...

Page 17: ...uipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compli...

Reviews: