The use of the PowerPanel Plus™ software is optional.

  The UPS unit will provide full surge suppression and 

battery backup without the software.  You must use the software if you wish to have the automatic shutdown feature. 
 

POWERPANEL PLUS™ MAIN MENU 

 

1. 

Log Button:

  Click on the log button to 

open the Log Window.  

2. 

Power Button: 

 Clicking on the power 

button will stop the software. 

3. 

Minimize Button:

  Click this button to 

minimize the software. 

4. 

Setup Button:

  Click the setup button to 

open the Setup Window. 

5. 

Model: 

 This shows the model of the 

CyberPower UPS that is being used. 

6. 

Version:

  This shows the hardware version. 

7. 

Status Bar: 

 The area display messages 

about the status of the software. 

8. 

Schedule Button: 

 Click this button to 

access the Schedule Window. 

 

POWERPANEL PLUS™ MAIN WINDOW DESCRIPTION 

 

1. Input 

Voltage: 

 

This reading shows the current input voltage of the utility power.  The input normally 

appears in green, but will turn red if the input voltage is lower than 85v or higher than 150v. 

2. Battery 

Level: 

 

This indicator displays the current charge on the battery.  The indicator will display a red 

color when a power failure occurs. 

3. Frequency:

  This indicator displays the frequency of the utility power. 

4. Scheduled 

On:

  PowerPanel Plus™ can be scheduled to turn your computer system on.  It can only be 

set when a 

Scheduled Off

 is also set.  

Scheduled On

 settings that are set to occur within seven days 

will be displayed.   When the UPS is in standby, after the 

Scheduled Off

, the using battery and check 

battery indicators will flash in rotation. 

5. Final 

Countdown:

  When PowerPanel Plus™ detects that the utility voltage is below 85 volts or above 

150 volts, the 

Final Countdown

 will begin.  When the countdown reaches zero, PowerPanel Plus™ will 

save and close any open applications, and 
then shut down the operating system in an 
intelligent and orderly manner. 

6. 

Approximate Backup Time:

  This indicator 

shows the 

approximate

 amount of backup 

time that is available, based upon the battery 
capacity and the load on the system.  This 
indicator can appear in red, yellow, or green, 
depending upon the number of minutes 
available. 

7. Scheduled 

Off:

  PowerPanel Plus™ can be 

set to automatically shutdown the computer 
system at a user specified time.  

Scheduled 

Off

 settings that are set to occur within seven days will be displayed. 

8. Temperature:

  This indicator displays the internal operating temperature of the unit.  If the temperature 

exceeds 158°F (70°C), the indicator will change from green to red. 

9. Load 

Level:

  This indicator shows the % of capacity of the battery outlets that is currently being used.  If 

the load level exceeds 90%, the indicator will change to a red color. 

10. Output 

Voltage:

  This indicator shows the output voltage of the UPS. 

 

Summary of Contents for CPS825AVR

Page 1: ...User Manual for CPS825AVR with USB Interface and PowerPanel Plus Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT www cyberpowersystems com faqs htm...

Page 2: ...source before servicing the battery or installing a computer component DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applicatio...

Page 3: ...ard 1 UPS unit DESCRIPTION 5 Power Switch Can be used as the master on off switch for computer equipment connected to the battery power supplied outlets 6 Power On Indicator This LED is illuminated wh...

Page 4: ...ephone icon can be used to protect a telephone or fax machine line 5 Plug the UPS into a properly grounded wall outlet Make sure the wall outlet is protected by a fuse or circuit breaker and does not...

Page 5: ...e will appear on your screen for a few seconds and then minimize It will appear as a blue and white battery icon located in the system tray near the clock FOR WINDOWS NT 1 Click on Start point to Sett...

Page 6: ...o an AC outlet turn the UPS on and then start your computer 8 Windows will find New Hardware 9 Insert the PowerPanel Plus primary disk into the floppy drive 10 Follow the on screen instructions 11 Onc...

Page 7: ...n your computer system on It can only be set when a Scheduled Off is also set Scheduled On settings that are set to occur within seven days will be displayed When the UPS is in standby after the Sched...

Page 8: ...ault Click this button to return the software to original factory settings 9 Cancel This button exits the window without saving changes 10 OK This button exits the window and saves changes 11 UPS Comm...

Page 9: ...will display the names and location of any files that were auto saved by the software TESTING YOUR UPS SYSTEM Once you have set up your UPS system you may wish to test it Make sure that the UPS has b...

Page 10: ...armful to skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove al...

Page 11: ...REMINDER Batteries are consider HAZARDOUS WASTE and must be disposed properly Contact your local government for more information about proper disposal and recycling of batteries...

Page 12: ...Beep Overload Occurs in the Battery power Supplied Outlets Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and turn the UPS on Off Off...

Page 13: ...the computer for an additional serial port Move the cable to this port The unit is not providing battery power Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This...

Page 14: ...erage under the Limited Warranty and the Power Control Guarantee Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to...

Page 15: ...mple a sales receipt that establishes you as the Initial Customer the original consumer purchaser of the Product within ten 10 days of the event for which you want to make a claim for warranty service...

Page 16: ...volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10 100T Ethernet lines when properly installed and c...

Page 17: ...pment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for complian...

Reviews: