TROUBLESHOOTING 

-continued

Problem

Possible Cause

Solution

PowerPanel® is inactive 

(all icons are gray).

The unit is not providing battery 

power.

Shutdown your computer and turn

the UPS off.   ait 10 seconds and 

turn the UPS back on.   his should 

reset the unit.

The serial cable is not the cable 

that came with the unit.

Please use the serial cable  

that came with the unit for 

the software.

The USB power ports are  

not providing power to the 

connected devices.

The USB power port has Over  

Current Protection design. When 

the total current of connected  

devices is over 3.1A, the USB  

power ports will stop providing 

power to the connected devices.

Turn the UPS off and unplug  

at least one piece of device  

connected to the USB power  

port and then turn the UPS on.

W

T

 

Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com

Model

CST1500S

Capacity

1500VA / 900W

Nominal Input Voltage

120 Volts

Input Frequency

60 Hz +/- 3 Hz

On-Battery Output Voltage

120 VAC +/- 5%

Max. Load for UPS Outlets

(5 Outlets)

1500 VA / 900 W

Max. Load for Full-Time

Surge Protection Outlets

12 Amps

On-Battery Output Wave Form

Adaptive Sinewave

Operating Temperature

+ 32°F to 104° F / 0°C to 40°C

Operating Relative Humidity

0 to 95% non-condensing

Size (W x H x D)

14.2 in., 3.9 in., 10.4 in. (361 mm, 99mm, 264 mm)

Net Weight

24.7 lbs / 11.2 kg

Battery Type

CyberPower / RB1280X2B

Typical Battery Recharge Time

8 hours from total discharge under 100% load

Typical Battery Life

3 to 6 years, depending on number of discharge/recharge cycles

Recommended Battery

Sealed Maintenance Free Lead Acid Battery

Safety Approvals

UL1778, CSA C22.2 No 107.3, FCC/DoC Class B

TECHNICAL SPECIFICATIONS

Summary of Contents for CST1500S

Page 1: ......

Page 2: ...ing equipment to the unit CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit over current protec tion in accordance with the National Electric Code ANSI NFPA 70 CAUTION Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equip ment ANSI NFPA 75 CAUTION Do not dispose of batteri...

Page 3: ...that the equipment plugged into the outlet does not exceed the UPS unit s rated capacity 1500VA 900W for CST1500S If the rated capacities of the unit are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 There are many factors that can affect the amount of power that your computer system will require It is suggested that the load placed o...

Page 4: ......

Page 5: ...e suppression outlets for connected equipment to ensure temporary uninterrupted operation of your equipment during a power failure DO NOT plug a laser printer paper shredder copier space heater vacuum sump pump or other large electrical devices into the Battery and Surge Protected Outlets The power demands of these devices may overload and damage the unit 9 Full Time Surge Protection Outlets The u...

Page 6: ......

Page 7: ......

Page 8: ... Possible Cause Solution Circuit breaker button is projecting from the back of the unit Circuit breaker has been tripped due to an overload Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by depressing the button and then turn the UPS on The UPS does not perform expected runtime Battery not fully charged Recharge the battery by leaving the UPS ...

Page 9: ...d then turn the UPS on W T Additional troubleshooting information can be found at Support at www CyberPowerSystems com Model CST1500S Capacity 1500VA 900W Nominal Input Voltage 120 Volts Input Frequency 60 Hz 3 Hz On Battery Output Voltage 120 VAC 5 Max Load for UPS Outlets 5 Outlets 1500 VA 900 W Max Load for Full Time Surge Protection Outlets 12 Amps On Battery Output Wave Form Adaptive Sinewave...

Page 10: ......

Reviews: