User’s Manual for

CyberShield

DTC50U12V3

CyberShield UPSs are designed to provide a local power solution for 
cable telephony, wireless local loop (WLL), and fiber to the home
(FTTH) broadband equipment. 

IMPORTANT SAFETY WARNINGS 

(SAVE THESE INSTRUCTIONS)

INSTALLATION

OVERVIEW

DESKTOP USE:
1.) Open the battery door at the back of the DTC50U12V3 and connect the battery wires.
2.) Plug AC power cable into wall outlet.
3.) Connect the communication cable and simply place the DTC50U12V3 unit on or
     underneath desk to begin backing up the optical home network.

BATTERY REPLACEMENT

As long as utility power is on, you may leave the UPS and connected equipment on while replacing a new 

battery. (For service personnel reference only)

COLD START

Step 1:

Connect the AC cable to the wall outlet.

Step 2:

Connect the communication cable between the DTC50U12V3

and the ONT device.

Step 1:

a. Slide off the battery

    cover at the back of the

    DTC50U12V3 unit.

Step 2:

a. Remove the battery from

    the enclosure.

b. Disconnect both battery

    cable connectors.

Step 3:

a. Install the new battery by connecting

    the red lead to the positive terminal

    and the black lead to the negative

    terminal.

b. Slide the battery back into the

    compartment.

c. Replace battery cover to resume

    normal operation.

Step 3:

Install the cable retainer to secure the

commnication cable.

Step 4:

Use the enclosed wall mount template to locate screws on the

wall. Hang the DTC50U12V3 on the screws which are located 

on the wall.

The cold start feature is to supply power to the UPS and connected equipment when the UPS 
shuts down and no utility power is available. Before using the cold start feature, please make sure 
that the battery is properly charged. To turn on the cold start feature, please press and hold the 
cold start button until 4 LED indicators light up.

This manual contains important instructions regarding the installation and operation of this device.  
Read this manual thoroughly before attempting to unpack, install or operate this device.

CAUTION!

The battery can energize hazardous live parts inside even when the AC input power is 

disconnected.  

CAUTION!  

To prevent the risk of fire or electric shock, install in a temperature and humidity 

controlled indoor area, free of conductive contaminants. (Please see specifications for 

acceptable temperature and humidity range.)  

 
 

CAUTION!  

To reduce the risk of electric shock, do not remove the cover. No user serviceable 

parts inside include battery. Please contact our company or our dealer directly.

 

CAUTION!

  When replacing batteries, the replacement should have the same rating as follows, 

  Listed/Certified Valve Regulated Lead Acid Battery, 12V, max. 9Ah.  

 

CAUTION!

Risk of Energy Hazard, battery. Before replacing batteries, remove conductive jewelry

such as chains, wrist watches, and rings and use tools with insulated handles. High 

energy through conductive materials could cause severe burns.  

 
 
 

CAUTION!

  Do not dispose of batteries in a fire. The battery may explode if improperly disposed. 

  Recycle batteries in accordance with local regulations.  

 

CAUTION!

CAUTION!

CAUTION!

  Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It 

  may be toxic.  

 

The UPS battery is charged when it is connected to utility power. The battery is fully 

charged during the first 

24 hours

 of normal operation. Do not expect full battery run 

capability during this initial charge period.

 7

6

5

4

ALARM SILENCE

The audible alarm will be enabled when the unit is operating from battery or battery power is low.
Press the Alarm Silence button for 0.5 seconds, the unit will beep once confirming that audible
alarms have been temporary disabled for 24 hours. Press this button one more time for 0.5 seconds 
to enable audible alarms again. The unit will beep twice confirming that audible alarms have been 
enable. Or press and hold the Alarm Silence button for 15 seconds the units will beep once confirm

-

ing that audible alarms have been disabled permanently. To restore the audible alarm, press and 
hold the Alarm Silence button for 15 seconds and the unit will beep twice confirming that audible 
alarms have been enabled.

WALL MOUNT USE:

1

2

3

8

LED Indicator
Alarm Silence Button
Cold Start Button
Cable Retainer Installation Point
Communication Cable Connector
AC Power Cable Connector

Battery Cover

1
2
3
4
5
6
7
8

External Battery

 

Connector

LED INDICATOR

DC

BATTERY

SYSTEM 

STATUS

MUTE

Green

Green

Orange

Red

Indicates normal mode of operation.

Indicates the battery is supplying the power. At 45% battery capacity, 

the LED will flash and then alarm will beep 4 times per minute.

Press and hold the button “Alarm Silence” for 0.5 seconds to silence 

the audible alarm for 24 hours, and the LED will flash.

Battery replacement required. Alarm will beep once every 15 minutes. 

The LED also illuminates when battery is absent.

The recommended capacity of an external battery is less than 100Ah. External batteries 

should be fully charged before used.

Indicator    Color    Condition

Number Description

Recommended Screw Dimension

Mounting Surface