IMPORTANT SAFETY INSTRUCTIONS

 

 

1

 

 

 

This manual contains important instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual 
thoroughly before attempting to unpack, install, or operate the UPS. 

 

CAUTION!   

The  UPS  must  be  connected  to  a  grounded  AC  power 

outlet with fuse or circuit breaker protection. DO NOT plug the UPS into 
an outlet that is not grounded. If you need to power-drain this equipment, 
turn off and unplug the unit.

 

CAUTION!   

The  battery  can  power  hazardous  components  inside  the 

unit, even when the AC input power is disconnected.

 

CAUTION!   

The UPS should be placed near the connected equipment 

and easily accessible. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a 

temperature  and  humidity  controlled  indoor  area,  free  of  conductive 
contaminants. (Please see specifications for acceptable temperature and 
humidity range).

 

CAUTION!    (No  User  Serviceable  Parts):

  Risk  of  electric  shock,  do 

not  remove  cover.  No  user  serviceable  parts  inside.  Refer  servicing  to 
qualified service personnel.

 

CAUTION!    (Non-Isolated  Battery  Supply): 

Risk  of  electric  shock, 

battery circuit is not isolated from AC power source; hazardous voltage 
may exist between battery terminals and ground. Test before touching.

 

CAUTION!   

To  reduce  the  risk  of  fire,  connect  the  UPS  to  a  branch 

circuit with 12 amperes (OL1000) / 15 amperes (OL1500) / 20 amperes 
(OL2200)  /  30  amperes  (OL3000)  maximum  over-current  protection  in 
accordance with the National Electric Code, ANSI/NFPA 70.

 

CAUTION!   

The AC outlet where the UPS is connected should be close 

to the unit and easily accessible. 

CAUTION!   

Please  use  only  UL-marked  mains  cable,  (e.g.  the  mains 

cable of your equipment), to connect the UPS to the AC outlet.

 

CAUTION!   

Please  use  only  UL-marked  power  cables  to  connect  any 

equipment to the UPS. 

CAUTION!   

When installing the equipment, ensure that the sum of the 

leakage  current  of  the  UPS  and  the  connected  equipment  does  not 
exceed 3.5mA.

 

CAUTION!   

The  OL1000  /  OL1500  /  OL2200  /  OL3000  models  may 

only be installed by qualified maintenance personnel..

 

CAUTION!   

Do not unplug the unit from AC Power during operation, as 

this will invalidate the protective ground insulation. 

CAUTION!   

To avoid electric shock, turn off and unplug the unit before 

installing  the  input/output  power  cord  with  a  ground  wire.  Connect  the 
ground wire prior to connecting the line wires! 

CAUTION!   

Do not  use an improper size power cord  as it may cause 

damage to your equipment and cause fire hazards. 

CAUTION!   

Wiring must be done by qualified personnel.

 

CAUTION!    DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT 
EQUIPMENT!

    Under  no  circumstances  this  unit  should  be  used  for 

medical applications involving life support equipment and/or patient care.

 

CAUTION!    DO NOT USE WITH OR NEAR AQUARIUMS!

    To reduce 

the risk of fire, do not use with or near aquariums.    Condensation from 
the  aquarium  can  come  in  contact  with  metal  electrical  contacts  and 
cause the machine to short out. 

CAUTION!   

Do  not  dispose  of  batteries  in  fire  as  the  battery  may 

explode. 

CAUTION!   

Do not open or mutilate the battery, released electrolyte is 

harmful to the skin and eyes. 

CAUTION!   

A battery can present a risk of electric shock and high short 

circuit  current.  The  following  precaution  should  be  observed  when 
working on batteries 
1.

 

Remove watches, rings or other metal objects. 

2.

 

Use tools with insulated handles. 

CAUTION!   

The  unit  has  a  dangerous  amount  of  voltage.  When  the 

UPS  indicators  is  on,  the  units  may  continue  to  supply  power  thus  the 
unit’s outlets may have a dangerous amount of voltage even when it’s not 
plugged in to the wall outlet. 

CAUTION!   

Make  sure  everything  is  turned  off  and  disconnected 

completely before conducting any maintenance, repairs or shipment. 

CAUTION!   

Connect the Protection Earth (PE) safety conductor before 

any other cables are connected. 

WARNING!    (Fuses): 

To  reduce  the  risk  of  fire,  replace  only  with  the 

same type and rating of fuse. 

 

 

DO  NOT  INSTALL  THE  UPS  WHERE  IT  WOULD  BE  EXPOSED  TO 
DIRECT SUNLIGHT OR NEAR A STRONG HEAT SOURCE! 

DO  NOT  BLOCK  OFF  VENTILATION  OPENINGS  AROUND  THE 
HOUSING! 

DO  NOT  CONNECT  DOMESTIC  APPLIANCES  SUCH  AS  HAIR 
DRYERS TO UPS OUTPUT SOCKETS! 

SERVICING  OF  BATTERIES  SHOULD  BE  PERFORMED  OR 
SUPERVISED  BY  PERSONNEL  KNOWLEDGE  OF  BATTERIES  AND 
THE 

REQUIRED 

PRECAUTIONS. 

KEEP 

UNAUTHORIZED 

PERSONNEL AWAY FROM BATTERIES!

 

Summary of Contents for OL1000ERTXL2U

Page 1: ...r s Manual OL1000RTXL2U OL1500RTXL2U OL2200RTXL2U OL3000RTXL2U CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 877 297 6937 Fax 952 403 0009 www CPSww com K01 0000247 02 ...

Page 2: ...qualified maintenance personnel CAUTION Do not unplug the unit from AC Power during operation as this will invalidate the protective ground insulation CAUTION To avoid electric shock turn off and unplug the unit before installing the input output power cord with a ground wire Connect the ground wire prior to connecting the line wires CAUTION Do not use an improper size power cord as it may cause d...

Page 3: ...manual Register card Rackmount left rail Rackmount right rail Rackmount ears Stands 2 Phone line USB communication cable Serial Interface Cable RS 232 Flat head screws M5X8L 8 Pan head screws M5X12L 12 Plastic washers 8 Screw hole dust covers 10 PowerPanel Business Edition software CD ...

Page 4: ...nstallation The rails adjust to mount in 48 cm 19 inch panel racks from 52 to 91 5cm 20 5 to 36 inches deep Select the proper holes in the rack for positioning the UPS in the rack The UPS takes up position 1 through position 6 Step 3 Adjust rackmount rails to fit your rack Attach the rackmount rail to your rack with two M5X12L screws and two plastic washers at the front of the rack Located in posi...

Page 5: ...RICAL INSTALLATION After completing the hardware installation of the UPS you are now ready to plug in the UPS and connect your equipment SAFETY PRECAUTIONS CAUTION Installation environment should be in a temperature and humidity controlled indoor area free of conductive contaminants Do not install this UPS where excessive moisture or heat is present Please see specifications for acceptable tempera...

Page 6: ...ephone fax machine or network device 5 Press the ON OFF switch to turn the UPS on The Power On indicator light will display when activated If an overload is detected an audible alarm will sound and the UPS will continuously emit two beeps per second For resetting the unit unplug some equipment from the outlets Make sure your equipment carries a load current within the unit s safe range refer to th...

Page 7: ...nected to NONCRITICAL outlets after a designated period of time 7 Serial Port Serial port provides communication between the UPS and the computer The UPS can control the computer s shutdown during a power outage through the connection while the computer can monitor the UPS and alter its various programmable parameters 8 USB port This is a connectivity port which allows communication and control be...

Page 8: ...Y Red Battery will soon need to be replaced due to insufficient runtime LCD SCREEN UPS STATUS LCD Screen UPS Status Description Line Mode UPS is operating in Line Mode Battery Mode UPS is operating in Battery Mode Bypass Mode UPS is operating in Bypass Mode Manual Bypass UPS is operating in Manual Bypass ECO Mode UPS is operating in ECO Economy Mode BUTTON OPERATION Button Operation Description ON...

Page 9: ... XXX XV Displays the Output Voltage O P Freq XX XHz Displays the Output Frequency I P Volt XXX XV Displays the Input Voltage I P Freq XX XHz Displays the Input Frequency O P Load XXX Displays the Output Load as a Percentage of Maximum load O P Amp X XA Displays the Output Current O P Watt XXXXXW Displays the Output Wattage O P VA XXXXXVA Displays the Output VA BAT Volt XXX XV Displays the Battery ...

Page 10: ... to select the Language submenu 6 Press the and buttons to scroll to the language that you want to select You may be prompted to save the selection if so press the ENTER button to save the setting 7 Press the ESC button to cancel or return to previous LCD menu LCD SETTINGS CONFIGURATION There are 22 UPS settings that can be configured by the user 1 Press the ENTER button to activate the MAIN MENU ...

Page 11: ... Français French Deutsch German English Generator Mode Disable Enable Disable Communication Disable Enable Enable Dry Relay Set I P Power Fail Battery Low Summary Alarm UPS On Bypass UPS Fail I P Power Fail Converter Mode Converter Off O P Freq 50Hz O P Freq 60Hz Converter OFF Screen Saver Disable 1 Minutes 5 Minutes 5 minutes Clear Event Log Activate None Button OFF LOCK Disable Enable Disable Ch...

Page 12: ...st portion of the LCD screen and the unit will perform a manual battery test GRAPHICAL LOAD BATTERY CAPACITY DISPLAY 1 Press the ESC button to return to UPS Status 2 Press the and buttons to scroll to the LOAD and BAT Capacity 3 Press the and buttons to scroll to the Charging or Discharging Capacity Discharging Capacity The LCD screen displays the remaining battery capacity with a graphical icon w...

Page 13: ... figure WALL MOUNTING INSTRUCTIONS Step 1 Remove the Multifunction LCD Module Unscrew the right panel of the UPS Separate the right panel from the UPS Gently lift the LCD module out Reinstall the right panel Step 2 Rotate the DB26 Connector of LCD Module Step 3 Connect the DB26 Cable Connect the DB26 cable from LCD module to the Remote Control Port on the front panel as shown in the following figu...

Page 14: ...s and may be toxic CAUTION To avoid electric shock turn off and unplug the UPS from the wall receptacle before servicing the battery CAUTION Only use tools with insulated handles Do not lay tools or metal parts on top of the UPS or battery terminals Replacement Batteries Please refer to the front side of the UPS for the model number of the correct replacement batteries For battery procurement log ...

Page 15: ...26 150 Load for 10 sec Battery Mode 105 130 Load for 10 sec 131 150 Load for 2 sec Short Circuit Protection UPS Output Cut off Immediately or Input Fuse Circuit Breaker Protection Battery Specifications 3 12V 9AH 6 12V 9AH Recharge Time Typically 4 hours Sealed Maintenance Free Yes Hot Swappable Yes Status Indicators LCD Screen Multi Function LCD Readout that Supports Multi Language Interface 19 T...

Page 16: ...he EPO connection Wiring Fault Line and neutral wires are reversed Exchange line and neutral wires Missing ground wire Connect ground wire No ground wire Disable Wiring Fault alarm on LCD panel Line Abnormal Wrong utility power backed up during UPS auto restart Check whether voltage or frequency of utility power is out of range Output Short Output short circuit Your attached equipment may have pro...

Page 17: ...e to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions within 10 days of the occurrence 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Ini...

Page 18: ... 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T...

Page 19: ...l interference in which case the user will be required to correct the interference at his own expense Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits This document is believed to be accurate but CyberPower reserves the right to change or correct the contents and does not assume any responsibility for omissions or errors Need Additional Help Fe...

Reviews: