Product Features (2U Series)

Front panel description

NEMA Type

Bank 1 , 20A

Bank 2 , 20A

2

1

3

4

5

6

7

8

16

15

14

13

12

11

10

9

Tx/Rx

Link

Amps

Volts

KW

- Warning

- Overload

B1

B2

- Normal

Select

YU0-0000028-00

Reset

A. Power Cord

B. AC Output Outlets

C. Input Circuit Breaker

D. Current Level

E. Input Voltage

F. Power

G. Load Indicator

H. Ethernet Port

I.  Tx/Rx Indicator

J.  Link Indicator

K. Outlet Indicator

  (switched series only)

L.  Serial/ENVIROSENSOR Port 

  (RJ45 modular port)

M. Select Button

N. PDU Status Screen

O. Reset Button

Rear panel description

IEC Type

Technical Specification

Bank 1 , 15A

Bank 2 , 15A

200-240VAC

50/60 Hz

24A MAX

12A MAX PER OUTLET

2

1

3

4

5

6

7

8

16

15

14

13

12

11

10

9

Tx/Rx

Link

Amps

Volts

KW

- Warning

- Overload

B1

B2

- Normal

Select

YU0-0000028-00

Reset

A. External Site Ground

A

100-120VAC
50/60 Hz
24A MAX

Installation Guide

CAUTION!!

Please use only the provided screws through the entire installation process.

Horizontal Installation

For 1U Model

Step 1. Mounting Bracket Installation

            Use the provided Mounting Bracket Screws (8) to attach the SHORT 

            Mounting Brackets (2) to the PDU.

If you plan on attaching the Cord Retention Tray to the PDU, you 

will need to use the LONG Mounting Brackets (2).

Step 2. PDU Mounting

            Use the supplied Washers (4) and Screws (4) to secure the PDU to 

            your existing rack system.

B

K

A

G

H

C

I

J

L

N

F

D

M

O

E

B

K

A

G

H

C

I

J

L

N

F

D

M

O

E

Model Name

PDU30SWT16FNET

PDU30SWHVT16FNET

PDU30MT16FNET

PDU30MHVT16FNET

Input

  Nominal Voltage

100-120V

200-240V

100-120V

200-240V

  Frequency
  Derated Input
  Current
  Plug Type

NEMA L5-30P

NEMA L6-30P

NEMA L5-30P

NEMA L6-30P

  Power Cord Type
  Power Cord
  Length

Output

  Nominal Voltage

100-120V

200-240V

100-120V

200-240V

  Derated Output
  Current

  Bank Number

  Outlet Type

NEMA 5-20R

IEC-320 C13

NEMA 5-20R

IEC-320 C13*12/

IEC-320 C19*4

  Outlet Number

Circuit Breaker
Networking
  

Protocol Support

  

Connectivity

Physical

  Dimension
  (H x W x D)

Environmental

  Humidity
  Altitude
  Temperature

Safety Approvals

  Certifications

Warranty

  Product Warranty

3 years

UL 60950-1, CSA C22.2, FCC Class A

3.5" x 17.05" x 4.41"/88mm x 433mm x 112mm

2

RJ45

16

Yes

TCP/IP, UDP, DHCP, SNMP, HTTP

0 to 95% Non-condensing

14700 ft/4500 m

32

 to 104

/0

 to 40

SR (10 AWG)

  Derated Output
  Current
  (each bank)

)

U

2

(

 

s

e

i

r

e

S

 

d

e

r

o

t

i

n

o

M

)

U

2

(

 

s

e

i

r

e

S

 

d

e

h

c

t

i

w

S

50/60Hz

24A

10 ft/3.05 m

12 ft/3.65 m

15A

20A

15A

20A

24A

Summary of Contents for PDU15M8FNET

Page 1: ...Power Distribution Unit User Manual www CPSww com K01 0000181 02 ...

Page 2: ...U with Keyhole Mount 15 Electrical Installation 15 Network Installation 16 Operation 17 Metered Readout 17 Basic Operation 17 PDU Status Screen 17 Current Level 17 Input Voltage 17 Power 17 IP Address 17 Outlet Control Switched series only 17 LED Reversal 0U series only 17 Environmental Monitoring optional 18 LED Indicators 18 Device Reset 18 Remote Management 18 Unattended Automatic Shutdown 19 F...

Page 3: ... Bracket Mounting Screws Includes two spares PDU RJ45 DB9 Serial Port Connection Cable Cable Ties Qty 20 16 Outlets Qty 30 24 Outlets Cord Retention Tray Mounting Screws M3x6 Qty 10 for 16 Outlets Qty 14 for 24 Outlets Includes two spares 6 Flat Head M4x4 Bracket Mounting Screws Includes two spares Mounting Brackets x 2 Cord Retention Trays Qty 2 16 Outlets Qty 3 24 Outlets 6 M5x12 Screws 6 Washer...

Page 4: ... For 2U Series CyberPower Reliab ility Qualit y Value R User s Manual 3 4 Front panel description NEMA Type 1 2 3 4 5 6 7 8 Select KW Volts Amps Normal Warning Overload Tx Rx Link Reset YU0 0000026 00 PDU20SWHVIEC8FNET A Power Cord B AC Output Outlets C Current Level D Input Voltage E Power F Load Indicator G Ethernet Port H Tx Rx Indicator I Link Indicator J Outlet Indicator switched series only ...

Page 5: ...d Input Current P 0 2 5 A M E N P 0 2 5 A M E N P 0 2 5 L A M E N P 0 2 5 L A M E N Power Cord Type SR 12AWG Socket SR 12 AWG Socket Power Cord Length 12 ft 3 65 m 10 ft 3 05 m 12 ft 3 65 m 10 ft 3 05 m Output Nominal Voltage 100 120V 200 240V 100 120V 200 240V Outlet Type NEMA 5 20R IEC 320 C13 NEMA 5 20R IEC 320 C13 Outlet Number Networking Protocol Support Connectivity Physical Dimension H x W ...

Page 6: ...21 22 23 BANK 1 BANK 1 BANK 2 BANK 2 BANK 1 20A BANK 2 20A Output 100 120VAC 50 60HZ 24A MAX 8 16 24 A C F H J D E G I L N M O B K B K B K Model Name PDU20SWVT24FNET PDU20SWVHVT24FNET PDU20MVT24FNET PDU20MVHVT24FNET Input Nominal Voltage 100 120V 200 240V 100 120V 200 240V Frequency Plug Type NEMA L5 20P NEMA L6 20P NEMA L5 20P NEMA L6 20P Power Cord Type Power Cord Length Output Nominal Voltage 1...

Page 7: ...kets 2 to the PDU If you plan on attaching the Cord Retention Tray to the PDU you will need to use the LONG Mounting Brackets 2 Step 2 PDU Mounting Use the supplied Washers 4 and Screws 4 to secure the PDU to your existing rack system B K A G H C I J L N F D M O E B K A G H C I J L N F D M O E Model Name PDU30SWT16FNET PDU30SWHVT16FNET PDU30MT16FNET PDU30MHVT16FNET Input Nominal Voltage 100 120V 2...

Page 8: ... Use the provided Cable Ties to fasten each cord to the Cord Retention Tray Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the 8 supplied Cord Retention Tray Mounting Screws For 2U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the Mounting Brackets 2 to the PDU Step 2 PDU Mounting Use the supplied Wa...

Page 9: ...p 2 PDU Mounting Use the supplied Washers 2 and Screws 2 to secure the PDU to your existing rack system Vertical Installation 1U 0U Model Only For 1U Model Step 1 Mounting Bracket Installation Use the provided Mounting Bracket Screws 8 to attach the SHORT Mounting Brackets 2 to the PDU Step 3 Cord Retention Tray Installation optional Attach the Cord Retention Tray to the PDU with the supplied Cord...

Page 10: ...ommended Power Device Network Utility 1 Use the included PDU Software Installation CD to install the Power Device Network Utility program 2 Open the Power Device Network Utility software Start Power Device Network Utility 3 Highlight the PDU device from the list and select Edit and Setup device Assisted Setup from the menu 4 Configure the IP Address Subnet Mask and Gateway Address to match your ne...

Page 11: ...witched series only LED Reversal 0U series only CyberPower PDUs along with the environment sensor ENVIROSENSOR provide the function of temperature and humidity monitoring in a server closet and or datacenter remotely To connect the PDU with ENVIROSENSOR use the RJ45 Ethernet Cable Plug one end into the Serial ENVIROSENSOR port on the PDU and the other end into the RJ45 port on the ENVIROSENSOR as ...

Page 12: ...is successful by checking the Firmware version on the System About webpage Note Please do not turn the PDU off when processing the Firmware upgrade 19 20 Operation Troubleshooting Frequently Ask Questions FAQ Q What do I do if I ve lost the Administrator username and or password A Resetting the PDU will set the username and password back to system default Please see the Device Reset section to res...

Page 13: ...on Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our liability is limited to the amount if any stated in the Technical Specifications Who pays for shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that is damaged or...

Page 14: ... the default firewall alert message is shown as Figure 5 You need to allow the Power Device Network Utility access through the firewall Figure 3 Power Device Network Utility Getting Started The Power Device Network Utility scans the network for devices with MAC addresses that match CyberPower network hardware Once found the device s can then be figured with a specific IP address subnet mask and ga...

Page 15: ...all power devices Step 3 Authentication Enter the user name and password of the PDU device at the Authentication menu Shown in Figure 7 Note The default username is cyber and the default password is cyber Figure 7 Authentication screen Advanced Settings Timeout Settings The Timeout Setting Shown in Figure 8 Edit Timeout Settings is used to specify the wait time when scanning for network PDU device...

Reviews: