Yellow 

ON 

Beep twice every 30 seconds 

Battery Mode 

The UPS is providing battery power. 

Flash 

Rapid Beeping 

Low Battery 

The UPS will run out of battery power soon. 

Red 

ON, Flash once 
every 5 seconds 

Constant Tone 

Battery Output Short Fault 

Turn off the UPS and unplug at least one piece of 
equipment. 

ON, Flash twice 
every 5 seconds 

Constant Tone 

Overload Fault 

Connected equipment exceeds the rating of the unit. 
Turn off the UPS and unplug at least one piece of 
equipment. 

ON, Flash 3 times 
every 5 seconds 

Constant Tone 

Charger Fault 

Contact CyberPower for support 

ON, Flash 4 times 
every 5 seconds 

Constant Tone 

Hardware Fault 

Contact CyberPower for support 

Flash Constant 

Tone 

Overload 

Warning 

Connected equipment exceeds the rating of the unit. 
Turn off the UPS and unplug at least one piece of 
equipment. 

 

TECHNICAL SPECIFICATIONS 

 

 

TROUBLESHOOTING 

 

Problem 

Possible Cause 

Solution 

The UPS does not perform 
expected runtime. 

Batteries are not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is slightly worn out. 

Contact CyberPower Systems Technical Support. 

The UPS will not turn on. 

The unit is not connected to an AC outlet. 

The unit must be connected to a 220-240V outlet.     

The battery is worn out. 

Contact CyberPower Systems Technical Support. 

Mechanical problem. 

Contact CyberPower Systems Technical Support. 

Outlets do not provide 
power to equipment. 

Fuse is blown or breaker is tripped due to 
overload. 

Turn the UPS off and unplug at least one piece connected equipment. Unplug 
the power cord of the UPS then replace the blown fuse with a spare one or 
press the circuit breaker knob. Connect power cord then turn the UPS on. 
Make sure that your spare fuse meets the specification. 

Batteries are discharged. 

Allow the unit to recharge for at least 4 hours. 

Unit has been damaged by a surge or 
spike. 

Contact CyberPower Systems Technical Support. 

 

For more information, visit 

www.cyberpower.com

   

All rights reserved. Reproduction without permission is prohibited. 

 

 

Model 

 

UT650EG UT800EG 

Capacity  (VA/W) 

650/360 800/400 

Input 

Voltage Range 

165~290Vac 

Nominal Frequency 

50/60Hz +/-5Hz 

Output 

On Battery Output Voltage 

220/230/240Vac 

On Battery Output Frequency   

50/60Hz +/-1% 

Overload Protection 

Fuse 

Physical

 

Total UPS Receptacles 

Universal x 3 

Dimensions (W x H x D)(mm) 

84 x 174 x 280 

Weight 

3.8 kg 

4.0 kg 

Battery

 

Sealed Maintenance Free Lead Acid Battery 

RBP0119 x1 

RBP0143 x1 

Typical Recharge Time 

6 Hours to 90% from total discharge 

Warning Diagnostics 

Indicators 

Utility / Battery / Fault 

Audible Alarms 

On Battery, Low Battery, Overload, Fault 

Environmental

 

Operating Temperature 

0

C to 40

Operating Relative Humidity 

0 to 90% 