background image

                        

Shenzhen Zhiyong Electronics Co., Ltd.

 

 

  2   

1.

 

Introduction 

EM5040/5040A/5040B

 Line Impedance Stabilization Network is a kind of 

50uH+5Ω

||50Ω 

V  type    LISN.  This  product  can  provide  stable  impedance  from  9  kHz  to  30  MHz  RF  range  for 

DUT  and  reference.  At  the  same  time,  it  isolated  the  useless  signal  from  the  electric  network  to 

measurement  circuit  and  coupling  the  interference  voltage  of  the  DUT  to  the  input  port  of  the 

measurement  receiver.  The  product’s  performance  is  compliant  with  standard  requirements  of 

CISPR16-1-2 for V-networks. It suits conducted disturbance voltage measurement for single phase 

equipment  well.  The  standard  BNC  output  port  and  50Ω  output  impedance  make  the  device 

compatible  to  the  measurement  equipment  such  as  receiver  and  spectrum  analyzer  of  any 

manufacturer. The artificial hand of the product can simulate the handle device to measure.   

EM5040

 is a type of single phase standard LISN. 

EM5040A

 has a limiter (with attenuation of 

10dB) and an optional 150 kHz high pass filter. Users can choose to start from 9 kHz or 150 kHz 

according to corresponding standard. The built in transient limiter can effectively protect receiver or 

spectrum  analyzer  from  damage  caused  by  large  signal.  Users  can  connect  EM5040A  safely  to 

those devices without other limiter. 

On  the  bases  of  EM5040A, 

EM5040B

  is  added  the  function  used  for  common  mode  and 

differential  mode  measurement,  which  will  provide  assistance  for  EMI  debugging,  especially  for 

EMI filter. 

EM5040C 

LISN is a type of single line 

5uH+1Ω

|| 50Ω LISN. This product can provide 

stable  impedance  from  100  kHz  to  200MHz  range  for  DUT  and  reference.  At  the  same  time,  it 

isolated  the  useless  signal  from  the  electric  network  and  measurement  circuit  and  coupling  the 

interference voltage of the DUT to the input port of the measurement receiver. It is compliant with 

VDE0876  Part1  (onboard  power-supply  systems),  VDE0879  Part2,  CISPR16-1-2(Low-impedance 

power  supplies),  CISPR25  and  EMC  Directive  95/94/EG,  DIN40839,  IS07637,  MIL-STD-462, 

MIL-I-6181D, MIL-E-55031, DEF STAN59-41 and DO 160. 

 

 

 

 

 

 

 

 

 

CYBERTEK

Summary of Contents for EM5040

Page 1: ...ybertek cn Line Impedance Stabilization Network EM5040 9kHz 30MHz 16A EM5040A 9kHz 150kHz 30MHz 16A EM5040B 9kHz 150kHz 30MHz 16A with common mode and differential mode EM5040C 100kHz 200MHz 100A Shen...

Page 2: ...of many users have bad grounding but users don t know This is critically dangerous so the company require the users to have double protection users must install isolation transformer Users can buy it...

Page 3: ...a limiter with attenuation of 10dB and an optional 150 kHz high pass filter Users can choose to start from 9 kHz or 150 kHz according to corresponding standard The built in transient limiter can effec...

Page 4: ...500A Ground protection Side metal panel grounding Rear panel 4mm butterfly bolt grounding 2 M8 bolt The bottom metal panel connected to the ground plane with screws Output port Standard 50 BNC female...

Page 5: ...40B s have a same V type LISN section The difference is the subsequent signal processing section EM5040 only contain the basic Type V LISN section To protect the test receiver users should add limiter...

Page 6: ...introduction 1 L1 indicator When powered up the indicator will be lighted up blue 2 EUT power port The product s power port is Germany Standard At the same time the accessories in the product provide...

Page 7: ...g the phase line under test 5 9 kHz 150kHz Switch The filter switch 6 Channel Selection Switch the output signal to the corresponding ports including RF Output CM Output DM Output 7 Artificial Hand fu...

Page 8: ...rear panel Side metal ground panel is for ground protection Rear Panel Introduction Ground Port This port has 4mm butterfly bolt for ground protection only This is not for reference ground Power inpu...

Page 9: ...rd so theoretically there will be large leakage of current to ground A bad grounding can possibly cause deadly electric shock As a result the company requires the users The device must be well grounde...

Page 10: ...lded line A LISN B Isolation transformer C Receiver 6 Application of Common mode and Differential mode technology Using EM5040B The conduct disturbance voltage of the switch power supply can always be...

Page 11: ...on mode choke is effective for common mode interference but not differential mode interference Theoretically the controlling effect is better when inductance is great but the increase of the turns of...

Page 12: ...ce 7 Packing List Packing List EM5040 5040A 5040B EM5040C LISN 1 1 RF cable BNC male 2 meter N male 2 meter BNC female to N male 1 N A Germany to national standard port 1 N A Instruction book 1 Warran...