background image

Page 13 -- ML24V02A -- www.EclipseRackmount.com

 

 

< 4.2 > QD  ALARM Connection & Operation 

1.  ALARM I/O : 

This female type 9 pin D-sub connector is used for alarm sensor input and alarm output control connections. It provides 
Normal Open and Normal Close contacts for alarm out control. 

 

 

 

 

 

 

 

 

 

 

The Alarm Hold Time can be confi gured from 0 second to 99 minutes through system Setup menu.

2.  VCR Connection for Tape Recording Start and Stop Control :

Connecting the contacts of VCR RECORD and STOP switch to the alarm output NC and NO contacts will allow you to use 
an ordinary VCR to record for longer period of time. Combined with alarm sensor detection, the VCR will record only when
an alarm sensor is activated.

*. If more than one sensor have been trigged, VCR will start to record after the last trigged event.
*. In order to make use of the alarm called full screen display function, the VIDEO IN connector from the VCR has to be 
connected to LIVE monitor connector of the device. If more than one sensor are trigged, VCR will then record all the 
events in full screen mode accordingly.

Pin Assignment for Alarm Connector (female type)

PIN#

PIN#

PIN#

1

Sensor 1

4

Sensor 4

7

Normal Open Contact

2

Sensor 2

5

Reset In

8

Common Contact

3

Sensor 3

6

GND

9

Normal Close Contact

 

Summary of Contents for MD-19QD

Page 1: ...ual ML24V02A Generation 4 www EclipseRackmount com User Manual Designed Manufactured by Austin Hughes and Distributed by Eclipse Rackmount Inc 1U 19 Quad Display Drawer MD 19QD Options Available DC Po...

Page 2: ...e personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty If any part of the equipment becomes damaged or stops functioning have it checked by qual...

Page 3: ...P 4 5 P 6 Part 1 MD 19QD 1 1 Package Contents 1 2 Structure Diagram Dimensions 1 3 Installation Contents P 1 P 1 2 P 3 Contents Quad Display Connection Operation 4 1 QD Connection 4 2 QD ALARM Connect...

Page 4: ...not made to clean monitors and monitor screens can scratch the LCD display or strip off the finish Do not spray any kind of liquid directly onto the screen or case of your monitor Spraying liquids di...

Page 5: ...l membrane Thumb Screw 1 1 Package Contents Part 1 MD 19QD unit X 1 6ft VGA cable X 1 Power cord X 1 M6 screw cage nut cup washer X 8 1 2 Structure Diagram The above package content is only for the ba...

Page 6: ...accessories options such as DC power 1 2 Dimensions Front View Side View UNIT mm 1mm 0 03937 inch Top View Model Product Dimension W x D x H Packing Dimension W x D x H Net Weight Gross Weight MD 19Q...

Page 7: ...n Step 3 Insert the left and right rear mounting brackets into the display drawer Step 1 1 3 Installation How to install Installation Slides Step 2 Measure the depth of the front and rear mounting rai...

Page 8: ...ess typ 250 Contrast Ratio typ 1000 1 Color 16 7 M Viewing Angle L R U D 80 80 80 80 Response Time ms 5 Dot pitch mm 0 294 Display Area mm 376 32H x 301 05V Surface treatment Haze 25 Hard coating Surf...

Page 9: ...860 x 140 mm 23 4 x 33 9 x 5 5 inch Net Weight 12 5 kgs 28 lbs Gross Weight 18 5 kgs 41 lbs Applicable Format VGA Input PC Signal 1280 x 1024 x 60 75Hz 1280 x 960 x 60Hz 1280 x 760 x 60 75Hz 1152 x 8...

Page 10: ...n for 5 seconds Display the OSD menu Power on off LCD Power light Green On Orange Power saving Membrane Switch Function OSD Conf guration Page Image for the brightness contrast color temp red green an...

Page 11: ...tage 12 Volt 24 Volt 48 Volt Input range 9 18V 18 36V 36 75V Input current No load 50 mA 50 mA 50 mA Full load 4950 mA 2450 mA 1220 mA Output rating Output voltage 12 Volt 12 Volt 12 Volt Output curre...

Page 12: ...These switches toggle be tween 75 and Hi Z impedance Incorrect termination will degrade the quality of the video signal All video inputs not looped through to another device the corresponding switche...

Page 13: ...l allow you to use an ordinary VCR to record for longer period of time Combined with alarm sensor detection the VCR will record only when an alarm sensor is activated If more than one sensor have been...

Page 14: ...ollowing 1 Connecting the Alarm Reset In contact pin 5 of the female type 9 pin D sub connector 8 to GND 2 The Alarm Duration time elapses 3 If the device is operated under Security Lock ON mode Push...

Page 15: ...age 15 ML24V02A www EclipseRackmount com h i z 1 2 3 4 75 IN OUT RS 232 ALARM dc 12V 1amp monitor vcr I O RS 232 Cable Wire Computer Remote Keypad Rear Panel 4 3 QD Remote Control Connection Operation...

Page 16: ...the male type 9 pin D sub connector on the real panel from it RS 232 port to control this device using standard uppercase ASCII codes 2 1 The ASCII command codes for the quad are listed in the table...

Page 17: ...continuously for more than 4 seconds to clear the alarm 3 Setup menu is switched ON by sending VCR DVR and Lock button codes together 4 Text Select and Cursor Control functions can be performed only u...

Page 18: ...ns of the unit BYTE 1 Status code for normal operation modes Channel Select 1110 CH1 1101 CH2 1011 CH3 0111 CH4 Display Mode 0 Quad screen display 1 Full Screen display Auto sequencing mode 0 Auto seq...

Page 19: ...CH4 activated BYTE 2 Status code for alarm operations The first 4 bits show the sensor activated alarm status of each channel next 4 bits show the video loss alarm status of each channel The digit 1...

Page 20: ...p buttons Push these two buttons simultaneously to get into Menu Setup mode and display page 1 of system setup menu Push these two buttons simultaneously again to display page 2 of the setup menu Use...

Page 21: ...8 characters may be entered for each video channel The available alphanumeric characters are 0 1 2 3 4 5 6 7 8 9 A B C D X Y Z space 1 2 DWELL Time setup The Dwell time menu permits setting the dwell...

Page 22: ...nected type of sensor a blinking message will display In this case the buzzer will be activated when you exit the setup operation 2 2 Alarm Sensitivity Alarm sensitivity can be programmed to different...

Page 23: ...the still screen mode is desired first turn the quad display button 4 to ON to set the unit to display in the quad mode At this time you may press any of the four channel selection buttons 5 to freez...

Page 24: ...yback mode Under this mode if the device is on quad display mode a pr recorded quad display video in the tape will be shown on the screen If the device is in Full screen display mode push any channel...

Page 25: ...Live Monitor 1 0 Vpp 75 Ohm x 1 Loop Through Out 1 0 Vpp 75 Ohm x 4 VCR Output 1 0 Vpp 75 Ohm x 1 Auto Gain Control Yes Time Date Yes On Screen Display Yes Camera Title 8 Character Title Display Forma...

Page 26: ...pecifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective ow...