Cybex Arc Trainer 610A Service Manual
Service
Page 4-26
B.
Using a 3/16” Allen wrench, attach each connecting rod with a screw removed in step 3A. See
Figure 4.
21. Attach the access cover.
A.
While being sure not to pinch any cables, place the access cover in position.
B.
Using a Phillips head screwdriver, attach the four screws removed in step 2A. See Figure 2.
22. Test the unit for proper operation.
A.
Connect the power cord into the power outlet.
B.
Turn the main power switch above the power inlet to the on (I) position.
C.
Operate the unit at all levels to verify proper operation.
Lower Pillow Blocks
Tools Required
• Phillips head screwdriver
• 3/16” Allen wrench
• 1/8” Allen wrench
• 2.5” (6.3 cm) Wooden block
• 9/16” Socket wrench
• 9/16” Open end wrench
! WARNING: Disconnect the power cord before beginning this procedure. Keep wet items away
from inside parts of the unit. Electrical shock could occur even if the unit is
unplugged.
1.
Elevate the unit and disconnect the power source.
A.
Plug the power cord into the power outlet.
B.
Enter
Test Mode.
C.
Elevate the unit to a minimum of level 7 incline.
D.
While the unit is elevated, turn the main power switch to the off (O) position and unplug the
power cord from the power outlet.
2.
Remove the access cover.
A.
Using a Phillips head screwdriver, remove the four screws securing the access cover. See
Figure 2.
B.
Remove the access cover.
! WARNING: Flywheel may be hot. Wait until it cools before servicing.