Service
Page 4-37
Cybex Arc Trainer 610A Service Manual
7.
Attach the console mount.
A.
Insert the upper display
cable into the console
mount and place on top of
the base assembly. See
Figure 29.
B.
Using a 7/32” Allen
Wrench, attach the four
screws and four lock
washers securing the
console mount in place.
5.
Connect the cables.
A.
Connect these cables into
the display board: the
display cable; the two
upper switch membrane connectors; the lower switch membrane connector; the contact heart
rate cable and the polar heartrate cable. See Figure 28.
6.
Check the connections:
A.
Check to see that all of the cables are connected firmly in their proper place.
7.
Secure the console back.
A.
While being sure not to pinch any cables, use a Phillips head screwdriver to tighten four screws
securing the console front to the console back removed in step 2B.
B.
Using a Phillips head screwdriver secure the access cover to the console back with the screw
removed in step 2A.
Figure 29
Upper
Display
Cable
Lower
Display
Cable
Contact Heart
Rate Cables
Console
Assembly
Washers (4)
Screws (4)
Lower Display Cable
Tools Required
• Flat head screwdriver
• Phillips head screwdriver
• 9/16” Open-end wrench or socket wrench
• 3/16” Allen wrench
• Tape
• Wire Cutters
! WARNING: Disconnect the power cord before beginning this procedure. Keep wet items away
from inside parts of the unit. Electrical shock could occur even if the unit is
unplugged.
1.
Disconnect the external power source.
A.
Turn the main power switch above the power inlet to the off (O) position.
B.
Unplug the power cord from the power outlet.