Cybex Arc Trainer 750A/750AT Owner’s Manual
70
Error Codes
When an error has occurred, “ERROR #” will appear on the text display alternating with the message
“OUT OF ORDER.”
NOTE:
Log number will show in the Incline Display as L-01 through L-20.
Press
CLEAR
button and hold to clear all errors in log. The display reads “NO ERRORS” when log is
empty.
Press enter to exit out.
NOTE:
See contact information in
Customer Service
for all maintenance and service activities.
Incline and low battery errors are as follows:
Error Number Cause
Display
Reset/Remedy
24: Incline
moving
too slowly
Incline is commanded to
move, yet the change in
feedback is slower than the
minimum allowed.
None, stored error
only
Inspect and lubricate the
•
lead screw.
Re-calibrate the incline.
•
Measure the incline
•
potentiometer output.
The potentiometer
could be ‘bad’.
Replace the battery.
•
25: Incline
movement
feedback
stopped
Incline is commanded to
move yet the feedback
indicates the value is not
changing or ceases to
change as expected.
Dashes shown in
incline window.
Display attempts to
re-calibrate incline
position on entry to
Dormant Mode.
26: Incline
disabled
Incline feedback problems
could not be remedied by
re-calibrating after an Error
25.
Dashes shown in
incline window.
Incline is disabled.
Contact service
technician.
27: Low
Battery
Battery voltage is reported
to be below the limit of
10.7v DC and the controller
has issued the low battery
warning.
Dashes shown in
incline window.
Incline is disabled.
Further use will re-
charge the battery
and the error condition
will be cleared
automatically.
Summary of Contents for 750A
Page 20: ...Cybex Arc Trainer 750A 750AT Owner s Manual 20 2 4 14 5 12 11 13 19 18 20 17 1 3 750AT ...
Page 76: ......
Page 77: ......