Appendix A: Advanced Device Configuration
313
Understanding How the OnBoard Manages Communications With Devices
docs/OnBoard/Application_Notes/
Service_Processor_Related
. Also see the
Readme.txt
file.
Table A-2:
Device Type Differences
Protocol Device
Type
Differences
DRAC
DRAC III/XT is the only version tested and proven to work with the default
DRAC Expect script and command template. Compatibility with DRAC II or
IV service processors is not guaranteed. Some DRAC service processors
support sensors; modifications to the default DRAC template would be needed
to support sensors; modifications to the default DRAC Expect script would be
needed to take advantage of sensor alarms.
IPMI 1.5
Works without a command template and with the default scripts.
IPMI 2.0
The OnBoard administrator can support IPMI 2.0 type service processors with
the IPMI 2.0 RCMP+ encrypted protocol in either of the two following ways:
• Identify the service processor as a IPMI 1.5 type which enables the OnBoard
to communicate with the 2.0-type service processor in “v1.5 compatibility
mode.”
• Copy the
talk_generic_ipmi.exp
onto
talk_custom
N
.exp
and
follow the directions within the file to modify the script for IPMI 2.0 support.
• Modify the default
ipmi
script to support OEM extensions
See the following application note
•
IPMI_2.0.txt
RSA I
The RSA I card uses a curses-based interface. The OnBoard administrator can
try to enable authorized users to perform IBM service processor console,
power, and event log device management actions through a RSA I type service
processor by copying the
talk_rsa_I.exp
Expect script to
talk_custom
N
.exp
and following the directions within the script to
modify the script for RSA I support. As stated in the
RSA_I.txt
application
note, this script may not be compatible with all RSA I firmware versions, so it
cannot be guaranteed to work.
Summary of Contents for AlterPath OnBoard
Page 36: ...xxxvi AlterPath OnBoard Administrator s Guide...
Page 108: ...Understanding How Configuration Changes Are Handled 72 AlterPath OnBoard Administrator s Guide...
Page 116: ...Overview of Web Manager Menus 80 AlterPath OnBoard Administrator s Guide...
Page 146: ...Configuring Regular Users Wizard 110 AlterPath OnBoard Administrator s Guide...
Page 160: ...Upgrading AlterPath PM IPDU Software 124 AlterPath OnBoard Administrator s Guide...
Page 194: ...Configuring an Alternate Help File Location 158 AlterPath OnBoard Administrator s Guide...
Page 292: ...Configuring Private Subnets and Virtual Networks 256 AlterPath OnBoard Administrator s Guide...
Page 344: ...Using the create_cf Command When Troubleshooting 308 AlterPath OnBoard Administrator s Guide...