background image

5

Cyclone Canopy Installation - English

DAMAGE INSPECTION

•  Please fully inspect unit for damage before installation.

•  If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.

•  If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

•  If the unit is damaged by the installer (if other than the customer), repair of replacement must be made by arrangement between 

customer and installer.

•  Once installed, all damages will be assumed the responsibility of the installer.

DUCTING

•  To reduce the risk of fire, use only metal ductwork.

•  To reduce risk of fire and to properly exhaust air, be sure 

to duct air outside – do not vent exhaust air into spaces 

within walls, ceilings, attics, crawl spaces, or garages.

WARNING

•  Best to use rigid type metal ducts.  Flexible ducts can 

restrict airflow by more than 50%.

•  Reduce the number of transitions and turns as much as 

possible.  If a reducer is used, install a long reducer instead 

of a pancake reducer.  If turns and transitions are required, 

install them as far away from the opening as possible and 

as far apart between two as possible.

CAUTION

•  6” round ductwork must be used to maintain maximum 

air flow efficiency with  motors of 450 CFM or greater.  If 

the use of any size ducting is less than 6”, the warranty is 

automatically voided.

•  The venting duct must go horizontally or vertically up to the 

outside wall or the roof.  If it is turned downward anywhere 

in the venting system, the warranty is automatically voided.

WARNING

Fasten all connections with sheet metal screws and tape all joints 

with certified silver tape or duct. 

Do not cut a joist or stud unless absolutely necessary.  If a joist or 

stud must be cut then a supporting frame must be constructed.

Before making cutouts make sure there is proper clearance within 

the ceiling or wall for the exhaust vent.

Examples of different types of ventilation for island 

and wall mounted canopies:

Additional parts not provided. 

Roof Pitch with Cap

and Flashing

Side wall cap with

gravity damper

Soffit or crawl space

Side wall cap with

gravity damper

For the most efficient and quiet operation:

We recommend to install the duct elbow at least 18” from the top 

of the damper.

Summary of Contents for AB14

Page 1: ...nd local electrical codes READ AND SAVE THESE INSTRUCTIONS Wall Mount and Island Range Hoods SC B 300 SC B 500 HC400 AW00 SC B 301 SC B 501 HC401 AW01 SC B 502 ALW02 SC B 503 SC510 ALW10 SC B 513 HC413 SC B 514 HC414 ALW14 AW14 AB14 SCB516 SCB316 SC B 519 SC B 319 SI B 323 SI B 520 SI B 521 SI B 522 SI B 523 SI530 SI531 SI532 SCB711 SC712 SC B 715 ALW15 SCB717 SCB718 SC720 SC B 322 SC B 722 ALW22 ...

Page 2: ...2 Cyclone Canopy Installation English ...

Page 3: ...ack drafting Follow the heating equipment manufacturer s guideline and safety standards as published by the local code authorities 5 When cutting or drilling into walls or ceilings be careful not to damage existing electrical wiring and other hidden utilities 6 To reduce the risk of fire electric shock and to properly exhaust air ducted fans must always be vented outdoors Do not vent exhaust air i...

Page 4: ... Wall Mount Installation Tools and Materials Required 7 Wall Mount Installation Parts Supplied 7 Wall Mount Hood Installation 8 Island Installation Tools and Materials Required 9 Island Installation Parts Supplied 9 Island Hood Installation 10 Canopy Hoods Specifications 12 Troubleshooting 13 Control Panel 14 Maintenance 14 Cyclone Range Hoods Limited Warranty 15 ...

Page 5: ...educer If turns and transitions are required install them as far away from the opening as possible and as far apart between two as possible CAUTION 6 round ductwork must be used to maintain maximum air flow efficiency with motors of 450 CFM or greater If the use of any size ducting is less than 6 the warranty is automatically voided Theventingductmustgohorizontallyorverticallyuptothe outside wall ...

Page 6: ...st be grounded This appliance is equipped with a cord having a grounding wire or with a plug having grounding wire The grounding wire must be grounded properly in the junction box or the plug must be plugged into an outlet that is properly installed and grounded 1 Connect the power line ground wire to the green ground wire supplied with the hood 2 Connect the black power wire to the black wire sup...

Page 7: ...ONLY 2 Bottom Chimney Screws WALLMOUNTINSTALLATION TOOLSANDMATERIALSREQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phillips screwdriver 2 or driver bit Wire stripper or cutter Tape measure Aluminum foil tape and or duct tape Electrical supplies for wiring i e marrets electrical tape Hammer Jigsaw o...

Page 8: ...l 6 round adapter if not preinstalled 8 Remove the filters from the hood 9 Hang hood onto screws and hand tighten If possible use extra screws to further secure the hood to the wall from inside the hood 10 Install 6 round duct over the adapter connect it with the venting duct coming from the wall or ceiling Use metal foil duct tape to seal the joint 11 Install electrical connection Turn on the hoo...

Page 9: ...ALLATION TOOLS AND MATERIALS REQUIRED Electrical drill or ratchet driver drill bit for drilling pilot holes 1 drill bit for drilling electrical wiring access hole if applicable Phillips screwdriver 2 or driver bit Wire stripper or cutter Tape measure Aluminum foil tape and or duct tape Electrical supplies for wiring i e marrets electrical tape Hammer Jigsaw or saber saw Drywall stud if applicable ...

Page 10: ... construction codes and standards WARNING Install Mounting Bracket 1 Modify ceiling structure at hood location Install 2 4 cross framing between ceiling joists using ceiling mounting bracket dimension Figure 4 The framework must be sized to support the total weight of the hood 2 Finish ceiling surface Be sure to mark the location of the ceiling joists and cross framing Bring house wiring through f...

Page 11: ...pe Mounting Screws 3 Slide the lower and upper chimney flues over the installed mounting bracket and have a second person hold it to the ceiling 4 Attach the hood to mounting bracket using six screws three per side Figure 7 5 Slide the lower and upper chimney flues down on top of the hood Install the electrical connection and connect the duct to the rough in duct work in the ceiling Seal the joint...

Page 12: ...AINLESSSTEEL GLASS STAINLESS STEEL STAINLESSSTEEL GLASS STAINLESS STEEL STAINLESSSTEEL GLASS CONTROLS ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON ELECTRONIC PUSH BUTTON SPEED LEVELS 3 3 3 3 3 3 DELAY OFF YES YES YES YES YES YES LIGHTING 2 1 5W LED SI323 4 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED 2 1 5W LED SI523 4 1...

Page 13: ...utton seized 2 Loosen the switch mounting screws from back of the switch 3 The control panel or motherboard is defective 3 Changedefectivepart Servicingmayberequired The unit vibrates 1 The motor is not secured 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower wheel Servicing may be required 3 The hood is not secured in place 3 Check the installation of the hood 4 Venting du...

Page 14: ...Cleaning Clean with warm soapy water and a clean cloth Do not use corrosive or abrasive detergent or steel wool pads that can scratch the surface of the machine Use non abrasive stainless steel polish to buff out the luster and grain Scrub lightly The stainless steel filters trap residue and grease from cooking The filters should never have to be replaced but should be cleaned thoroughly every 30 ...

Page 15: ...ries for ducting c natural wear of the finish of the products or wear caused by improper maintenance use of corrosive and abrasive cleaning products d products or parts which have been subject to freight damage misuse negligence accident or any other circumstances beyond the control of The Company The warranty will be automatically void if any of the following apply i Commercial use of the product...