background image

16

V1.0

www.cyclopslighting.com

Model

FR-300C

Light source:

300 watts Cool white COB LED

1000-1800W tungsten equivalent

Color temperature:

5600K

LED life expectancy:

50,000 Hrs.

CRI: 

97, R9: ≥90

TLCI:

 ≥

96

Zoom range: 

15° to 50° motorized

Light output

8,500 Lux @ 5m @ 15°

Control protocols:

RDM, Artnet, DMX control

Control channels:

1, 2, 3, 4 CHs

5 Dimmer curves

Flicker free with selectable PWM

Color: 

 

Cool white

Input voltage:  

AC100-240V/50-60Hz

AC connection:

 

PowerCON in

 

                                                   

Technical specifications

Housing:                                                                           Aluminum

IP rating:                                                                           20

Operating temperature:                                       -5°C/45°C

DMX data in/out:

3-pin XLR in & out

Dimensions:        

428 x 295 x 451mm

Net weight:  

11 Kg (including barn door)

Color:     

Black

Housing: 

Aluminum

IP rating

20

Summary of Contents for FR-300C

Page 1: ...USER MANUAL FR 300C 300 watts Cool White LED Fresnel...

Page 2: ...ble 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM contr...

Page 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operati...

Page 4: ...door and color frame holder Handle Net out LCD display Menu button Up button Down button Enter button Net in Fuse Power in On off switch Safety cable anchor point Dmx out Dmx in Dmx signal indicator...

Page 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture if the pri...

Page 6: ...DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the...

Page 7: ...equirements The FR 300C LED zoom luminaire operates on 100 to 240 volts AC 10 auto ranging The lumi naire contains an auto ranging power supply Power linking between fixtures The fixture with powercon...

Page 8: ...e ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net subnet Channel 1 2 3 4CH Art Net channel mode Auto Program 001 00...

Page 9: ...Control menu The information menu will appear after the fixture is switched on In this menu the following status is dis played Main Menu Press the MENU button to enter the Main Menu interface Address...

Page 10: ...e If you set for example the ad dress in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512 data...

Page 11: ...pose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology Art Net designed by and copyright Artistic Licence Holdings Ltd For more detail explainati...

Page 12: ...ect Mode menu and press ENTER 3 Press DOWN menu and select Manual sub menu 4 Press ENTER and select Zoom in third menu 5 Rotate the rotary knob to control the dimmer right stop minimum zoom scale left...

Page 13: ...or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press the MENU button to enter the main menu 2 Press...

Page 14: ...55 Zoom from wide to narrow Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output...

Page 15: ...der next to the MAINS OUT socket on the connections panel To replace a fuse 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and rem...

Page 16: ...8 500 Lux 5m 15 Control protocols RDM Artnet DMX control Control channels 1 2 3 4 CHs 5 Dimmer curves Flicker free with selectable PWM Color Cool white Input voltage AC100 240V 50 60Hz AC connection P...

Reviews: