background image

3

V1.0

Caution!

Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric 

shock when touching the wires!

Avoid looking directly into the light source!

Wear protective glasses and other PPE (personal protective equipment) when working on or near 

the fixture.

For your own safety, please read this user manual carefully before you initial start-up.

Follow operating safety precautions and pay attention to warning signs methods and equipment 

on the user manual.

Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 

20 rating.

The ambient temperature must always be between -5° C and +45° C. 

Always make sure you are connecting this product to the proper voltage in accordance with the 

specifications in this manual or on the product’s specification label.Make sure it is grounded when 

using it!

Unplug mains lead before opening the housing!

Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture 

and the powercord from time to time.

Make sure to replace the fuse with another of the same type and rating.

Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot 

during operation. After use, wait for a cool-down period of at least 10 minutes before handling or 

transporting the device.

Every person involved with the installation, operation and maintenance of this device has to

- be qualified

- follow the instructions of this manual

- consider this manual to be part of the total product

- keep this manual for the entire service life of the product

- pass this manual on to every further owner or user of the product

- download the latest version of the user manual from the Internet

Introduction

Thank you for having chosen FR-300C . You will see you acquired a powerful and versatile device.

Unpack your item. Before you initial start-up, please make sure that there is no damage caused by trans-

portation. Should there be any, consult your dealer and do not use the device.

Safety instructions

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to 

ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warn-

ing notes written in this user manual. Always disconnect from the mains, when the device is not in use 

or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts 

inside the device. Maintenance and service operations are only to be carried out by authorized dealers.

Summary of Contents for FR-300C

Page 1: ...USER MANUAL FR 300C 300 watts Cool White LED Fresnel...

Page 2: ...ble 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM contr...

Page 3: ...the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operati...

Page 4: ...door and color frame holder Handle Net out LCD display Menu button Up button Down button Enter button Net in Fuse Power in On off switch Safety cable anchor point Dmx out Dmx in Dmx signal indicator...

Page 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture if the pri...

Page 6: ...DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the...

Page 7: ...equirements The FR 300C LED zoom luminaire operates on 100 to 240 volts AC 10 auto ranging The lumi naire contains an auto ranging power supply Power linking between fixtures The fixture with powercon...

Page 8: ...e ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net subnet Channel 1 2 3 4CH Art Net channel mode Auto Program 001 00...

Page 9: ...Control menu The information menu will appear after the fixture is switched on In this menu the following status is dis played Main Menu Press the MENU button to enter the Main Menu interface Address...

Page 10: ...e If you set for example the ad dress in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512 data...

Page 11: ...pose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology Art Net designed by and copyright Artistic Licence Holdings Ltd For more detail explainati...

Page 12: ...ect Mode menu and press ENTER 3 Press DOWN menu and select Manual sub menu 4 Press ENTER and select Zoom in third menu 5 Rotate the rotary knob to control the dimmer right stop minimum zoom scale left...

Page 13: ...or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press the MENU button to enter the main menu 2 Press...

Page 14: ...55 Zoom from wide to narrow Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output...

Page 15: ...der next to the MAINS OUT socket on the connections panel To replace a fuse 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and rem...

Page 16: ...8 500 Lux 5m 15 Control protocols RDM Artnet DMX control Control channels 1 2 3 4 CHs 5 Dimmer curves Flicker free with selectable PWM Color Cool white Input voltage AC100 240V 50 60Hz AC connection P...

Reviews: