background image

8

V1.0

Zoom

This function allows you to adjust the beam width of the fixture.

Step 1: Loosen the zoom buttons on the side of the device.

Step 2: Adjust the zoom by sliding the back lenshousing forward or backward.

Step 3: Tighten the zoom buttons.

Control Menu Map

MENU

SUB MENU

OPERATION

Addr

d001-d512

RDM/DMX address

CHnL

1CH

Channel mode

2CH
3CH
4CH

Strb

S.01-s.20

Strobe with spead increasing

uL--

u.000-u.255

Key control of dimmer

UOL

000-255

Rotary control of dimmer

nodE

nod.0

Dimmer speed 0 (no delay)

nod.1

Dimmer speed 1

nod.2

Dimmer speed 2

nod.3

Dimmer speed 3

nod.4

Dimmer speed 4 (slowest speed)

Id

Id.01-Id.66

 ID setting

tEnP

-25~100

Fixture temperature

UErn

Firmware version

rSEt

Reset

pnnF

(1.2~24.0)F

PWM refresh rate adjustment

Summary of Contents for FR-40W

Page 1: ...USER MANUAL FR 40W Warm White Super Compact LED Fresnel...

Page 2: ...ng the fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Addressing 7 Universal DMX Control 7 Rotary control 7 Zoom 8...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...esigned for indoor use only and must be used in a dry location with adequate ventilation Ensure that none of the fixture s ventilation slots are blocked Fasten the fixture to a secure structure or sur...

Page 5: ...ord To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment to be installed on it 2 Block access under the work area 3...

Page 6: ...n of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the...

Page 7: ...unit will start to listen to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixtur...

Page 8: ...MENU OPERATION Addr d001 d512 RDM DMX address CHnL 1CH Channel mode 2CH 3CH 4CH Strb S 01 s 20 Strobe with spead increasing uL u 000 u 255 Key control of dimmer UOL 000 255 Rotary control of dimmer n...

Page 9: ...dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Dimmer mode 000 255 Dimmer speed 0 no delay 000 255 Dimmer speed 1 000 255 Dimmer speed 2 000 255 Dimmer speed 3 000 255 Dimmer speed 4 slow...

Page 10: ...ct the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean th...

Page 11: ...LED Color temperature 3200 K LED life expectancy 50 000 Hrs CRI 97 R9 90 TLCI 98 Manual zoom Zoom range 25 to 90 manual Light output 14 000 Lux 1m 25 5 Dimmer curves Strobe Video flicker free PMMA po...

Page 12: ...12 V1 0 Please note All information is subject to change without prior notice 20 06 2018 156MM 211MM 306MM 230MM 279MM 185MM www cyclopslighting com...

Reviews: