background image

8

Version 1.0

4 Channels Mode

Function

Function Control

CH3

Dimmer mode

000-005: Menu setting
006-055: Dimmer speed 0 (no delay)
056-105: Dimmer speed 1
106-155: Dimmer speed 2
156-205: Dimmer speed 3
206-255: Dimmer speed 4 (slowest speed)

CH4

ID address setting

000-009: ID1-ID66
010-019: ID1
020-029: ID2
030-039: ID3
...
200-209: ID20
210: ID21
211: ID22
...
255: ID66

ID address selection

Each independent DMX address can have up to 66 ID addressed fixtures. An ID address of 0 will activate 

all ID address locations.

CH4 is used to select the target ID address.

DMX value

Function

DMX value

Function

DMX

 

value

Function

000-009

ID1-ID66

212

ID23

235

ID46

010-019

ID1

213

ID24

236

ID47

020-029

ID2

214

ID25

237

ID48

030-039

ID3

215

ID26

238

ID49

040-049

ID4

216

ID27

239

ID50

050-059

ID5

217

ID28

240

ID51

060-069

ID6

218

ID29

241

ID52

070-079

ID7

219

ID30

242

ID53

080-089

ID8

220

ID31

243

ID54

090-099

ID9

221

ID32

244

ID55

100-109

ID10

222

ID33

245

ID56

110-119

ID11

223

ID34

246

ID57

120-129

ID12

224

ID35

247

ID58

130-139

ID13

225

ID36

248

ID59

140-149

ID14

226

ID37

249

ID60

150-159

ID15

227

ID38

250

ID61

160-169

ID16

228

ID39

251

ID62

170-179

ID17

229

ID40

252

ID63

180-189

ID18

230

ID41

253

ID64

190-199

ID19

231

ID42

254

ID65

200-209

ID20

232

ID43

255

ID66

210

ID21

233

ID44

Summary of Contents for PAR-150CZ

Page 1: ...USER MANUAL PAR 150CZ 150 Watt Zoom Cool White LED PAR...

Page 2: ...a truss 4 Securing with a safety cable 4 DMX 512 connection connection between fixtures 4 Power connection 5 Operation 5 Control Menu Map 5 Addressing 6 Universal DMX Control 6 RDM control 6 Zoom fun...

Page 3: ...of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation oper...

Page 4: ...n be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down you can use an open type clamp such as a G clamp When installing in any othe...

Page 5: ...ed between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120...

Page 6: ...ing address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to listen to the same control signal fr...

Page 7: ...llows you to adjust the beam width of the fixture manually Simply rotate the rotary knob in the display panel to control the zoom right stop maximum spot left stop minimum spot DMX Protocol 1 Channel...

Page 8: ...address DMX value Function DMX value Function DMX value Function 000 009 ID1 ID66 212 ID23 235 ID46 010 019 ID1 213 ID24 236 ID47 020 029 ID2 214 ID25 237 ID48 030 039 ID3 215 ID26 238 ID49 040 049 I...

Page 9: ...solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tiss...

Page 10: ...rating temperature 5 C 45 C www cyclopslighting com Model PAR 150CZ Light source 150 watts Cool White COB LED Equal to HPL 750 Par Color temperature 5600K LED life expectancy 50 000 Hrs CRI 96 Ra 94 T...

Reviews: