background image

14

V1.0

DMX Protocol

1 Channel Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

2 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-255: Strobe with speed increasing

3 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Dimmer fine

000-255: 16 bit dimmer

CH3

Strobe

000-255: Strobe with speed increasing

Fixture Cleaning

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should 

be carried out periodically to optimize light output. Cleaning frequency depends on the environment 

in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend 

cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.

To clean the fixture:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure 

compressed air.

3.  Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent 

solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, 

clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented 

tissue or cotton swab moistened with glass cleaner or distilled water.

4. 

Check that the fixture is dry before reapplying power.  

Fuse Replacement

This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel.

To replace a fuse:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and 

rating only.

3.  Reinstall the fuseholder cap before reapplying power.

Troubleshooting

Listed below are a few common problems that you may encounter, with solutions.

The fixture does not work, no light

• 

Check the connection of power and main fuse. Be sure the external fuse has not blown.

• 

Measure the mains voltage on the main connector.

Summary of Contents for PR-300C

Page 1: ...USER MANUAL PR 300C 300 watts Cool White LED Profile ...

Page 2: ... 6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 10 Universal DMX Control 10 RDM control 10 Art Net protocol 11 Rotary Knob function 11 Set dimmer curves 12 Zoom 13 DMX Protocol 14 Fixture Cleaning 14 Fuse Replacement 14 Troubleshooting 14 The fixture does not work no light 14 Technical ...

Page 3: ...of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the ...

Page 4: ...4 V1 0 Overview ...

Page 5: ...ll over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails Mounting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging vertically down yo...

Page 6: ... DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected DMX 512 connection with DMX terminator For installations where the DMX cab...

Page 7: ...er Requirements The PR 300C luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Power linking between fixtures The fixture with powercon in and out socket Connect the power out to the power in socket in the next fixture till all are connected Caution maximum power linking 6 units Connection with the mains Connect the device to the mains wit...

Page 8: ... Net Mask for class C IP address Mode DMX 1 2 3CH DMX channel mode ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net subnet Channel 1 2 3CH Art Net channel mode Auto Program 001 008 Preset programs Speed 001 009 Programs speed Maunal Brightness 000 255 Dimmer 0 100 Strobe 000 255 Strobe with speed increasing Dimmer ...

Page 9: ...n Timeout 30S Display shut off time Never Screen Brightness 10 100 Display brightness Reset Yes No System reset Reverse Yes No Display reverse 180 degree Control menu The information menu will appear after the fixture is switched on In this menu the following status is displayed Main Menu Press the MENU button to enter the Main Menu interface ...

Page 10: ...have set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of the PR 300C which is 1 2 3 channels fixture If you set for example the address in the 1 channel mode to channel 2 the device will use the channel 2 for control Note After switching on the device will automatically detect whether DMX 512...

Page 11: ...unning on your PC or light console has to support Art Net protocol Art Net communication protocol is a 10 Base T Ethernet protocol based on the TCP IP Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology Art Net designed by and copyright Artistic Licence Holdings Ltd For more detail explaination of Art Net protocol please referring to...

Page 12: ...5 Rotate the rotary knob to control the dimmer right stop maximum output left stop zero output or strobe right stop maximum strobe left stop no strobe Note Rotary dimmer or strobe function works in information Menu and Mode Manual menu Up Down Enter function The knob can also act as up down and enter function 1 Press the MENU button to enter the main menu interface 2 Right rotation Down left rotat...

Page 13: ...e UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Press the UP or DOWN button to select Custom menu and press ENTER 5 Adjust fade in and fade out time to customize yout dimmer curves Time vary from 150 ms to 2230 ms Zoom This function allows you to adjust the beam width of the fixture Step 1 Loosen the zoom buttons on the side of the device Step...

Page 14: ...les from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened...

Page 15: ...MMA 5 Dimmer curves 16 bit dimmer Strobe Video flicker free with selectable PWM Intelligent temperature control Silent operation Control protocols Rotary DMX RDM Artnet Control channels 1 2 3 CHs Input voltage AC100 240V 50 60Hz DMX connections 3 pin XLR In Out male and female Power connections PowerCon In Out Dimensions 745 x 294 x 294mm Net weight 8 7 Kg including lens Color Black IP rating 20 O...

Reviews: