background image

14

V1.0

DMX Protocol

1 Channel Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

2 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Strobe

000-255: Strobe with speed increasing

3 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Dimmer fine

000-255: 16 bit dimmer

CH3

Strobe

000-255: Strobe with speed increasing

Fixture Cleaning

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should 

be carried out periodically to optimize light output. Cleaning frequency depends on the environment 

in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend 

cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.

To clean the fixture:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure 

compressed air.

3.  Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent 

solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, 

clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented 

tissue or cotton swab moistened with glass cleaner or distilled water.

4. 

Check that the fixture is dry before reapplying power.  

Fuse Replacement

This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel.

To replace a fuse:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and 

rating only.

3.  Reinstall the fuseholder cap before reapplying power.

Troubleshooting

Listed below are a few common problems that you may encounter, with solutions.

The fixture does not work, no light

• 

Check the connection of power and main fuse. Be sure the external fuse has not blown.

• 

Measure the mains voltage on the main connector.

Summary of Contents for PR-300W

Page 1: ...USER MANUAL PR 300W 300 watts Warm White LED Profile...

Page 2: ...6 DMX 512 connection connection between fixtures 6 Art Net Connection 7 Power connection 7 Operation 8 Control Menu Map 8 Control menu 9 Main Menu 9 Addressing 10 Universal DMX Control 10 RDM control...

Page 3: ...f the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operat...

Page 4: ...4 V1 0 Overview...

Page 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed below with a securely anchored safety cable that will hold the fixture if the prim...

Page 6: ...DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with th...

Page 7: ...r Requirements The PR 300W luminaire operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Power linking between fixtures The fixture with powercon in and...

Page 8: ...Net Mask for class C IP address Mode DMX 1 2 3CH DMX channel mode ArtNet Net 000 127 Set Art Net net SubNet 000 015 Set Art Net subnet in Art Net net Universe 000 015 Set Art Net universe in Art Net s...

Page 9: ...Timeout 30S Display shut off time Never Screen Brightness 10 100 Display brightness Reset Yes No System reset Reverse Yes No Display reverse 180 degree Control menu The information menu will appear a...

Page 10: ...ave set based on the quantity of control channels of the unit That means changing the settings of one channel will affect only the selected fixture In the case of the PR 300W which is 1 2 3 channels f...

Page 11: ...nning on your PC or light console has to support Art Net protocol Art Net communication protocol is a 10 Base T Ethernet protocol based on the TCP IP Its purpose is to allow transfer of large amounts...

Page 12: ...Rotate the rotary knob to control the dimmer right stop maximum output left stop zero output or strobe right stop maximum strobe left stop no strobe Note Rotary dimmer or strobe function works in inf...

Page 13: ...UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Press the UP or DOWN button to select Custom menu and press ENTER 5 Adjust fade in and fade out ti...

Page 14: ...es from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub glass su...

Page 15: ...snel lens adapter 25 50 PMMA 5 Dimmer curves 16 bit dimmer Strobe Video flicker free with selectable PWM Intelligent temperature control Silent operation Control protocols Rotary DMX RDM Artnet Contro...

Reviews: