OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor area. Connect the propane gas tank to the
regulator and turn the valve on the unit to the “off”position. Brush a soap and water mixture on all connections. Turn the gas supply on; if
bubbles occur on any connection there may be a leak.
If you smell gas or a leak is discovered turn the gas valve off, disconnect
propane gas tank and do not use the appliance until the leak is repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion you must replace the hose (if applicable).
Pumice stone/lava rocks/fireglass could pop up and strike somebody’s face during the 20 minutes after igniting. Flame height should be a
yellow/blue color between 2 - 10 inches in height.
Wait 5 minutes after extinguishing flame prior to placing a lid or protective cover on heating item.
TO LIGHT
1. Make sure the control knob is in the “off” position.See below figure A.
2. Remove door and slowly open the valve on the propane gas tank by turning the knob counterclockwise.
3. Replace the door on the body.
4. Push and hold in the electronic igniter to create sparks within the electrode, continue to hold.
5. Push in the control knob and turn to the “low” position. see figure below B.Keep holding down the control knob to allow gas to flow for
15 seconds.
6. If ignition doesn’t occur within a few seconds release the control knob and rotate to the “OFF”,see below figure A.
position. Wait for 5 minutes for gas to clear and then repeat the above lighting instructions.
7. Once the fire product is lit, the flame intensity may be controlled by turning the control knob between the “low” and “high”
positions.see figure below B and C.
Caution: *If the burner does not ignite with the valve open, gas will continue to flow out of the burner and could accidently ignite with risk of
injury.
TO EXTINGUISH
• Push the Control Knob and turn clockwise to the "OFF" position.
• Turn the cylinder valve on the gas tank clockwise to close the gas supply if not in use for a long time.(See figure below)
OWNER'S MANUAL PAGE 6 / 8