- 14 -
7. TEST THE INSULATED-GATE
BIPOLAR TRANSISTOR (IGBT)
In order to test the IGBT, set the multimeter to circuit continuity func-
tion (a beep is heard when the circuit is continuous) and then check
whether there is an electrical connection between the IGBT terminals.
Repeat the same procedure for all four IGBTs.
If there is an electrical connection (the meter beeps) between any IGBT
terminals, the IGBT is faulty.