3.3. Error E4
The control panel - module harness installed incorrectly
Faulty control panel - module harness Replaces control panel
Replaced induction module
NO
YES
N
O
YES
NO
YES
YES
NO
Check the correct operation of the hob Point
9.2.
Check if the control panel - module harness is installed correc
tly:
1. Are plugs correctly inserted into sockets?
2. Is the harness routed according to specification?
Point 11
Check the correct operation of the hob Point
9.2.
Replace the control panel.
Does the hob operate
correctly?
End of repair
Check the correct operation of the hob Point
9.2.
Check the correct operation of the hob Point
9.2.
Does the hob operate
correctly?
Does the hob operate
correctly?
End of repair
Replace the induction module while paying
special attention to the correct connection of
induction coils and temperature sensors
End of repair
Technician should note all defects found in the
following list:
Is the harness
installed correctly?
Check if there is an aluminium sticker "Amica Service Centre" —
if so,
carefully peel it off!
Install the control panel - module harness
according to specification. Point 11
Replace the control panel - module harness.
Make sure the installation is consistent with
the specification.
Summary of Contents for 4VI515 Series
Page 3: ... 3 1 HOB FEATURES AND COMPONENTS ...
Page 13: ... 13 2 single coils 6 dual coils 5 single coils ...
Page 18: ... 18 9 2 Check if neutral conductor for L1 phase is connected correctly ...
Page 19: ... 19 9 3 Check if L1 phase is connected correctly ...
Page 20: ... 20 9 4 Check if L2 phase is connected correctly ...
Page 21: ... 21 9 5 Check if coils are connected correctly ...