10
COMMAND
DESCRIPTION
PARAMETER
RGAA
Request Current Static
Gateway Address
NONE
SGAA X.X.X.X
Set Static Gateway
Address
X=0~255 (192.168.1.50)
RETIME
Request Current Ethernet
Timeout
NONE
SETIME N1
Set Ethernet Timeout
N1=
0(OFF)
, 1(10 Minutes),
2(20 Minutes), 3(30
Minutes), 4(40 Minutes),
5(50 Minutes), 6(60
Minutes)
RLINK
Request Ethernet Address NONE
RMUTE
Request Current Mute
NONE
SMUTE N1
Set Mute Audio
N1=0(Unmute), 1(Mute)
RPOW
Request Current Power
State
NONE
SPOW N1
Set the Unit Power On/Off
N1=0(Off), 1(On)
RVER
Request Version
NONE
SREL
Relink the Unit in 2
Seconds
NONE
SDEF
Reset the Unit to Factory
Defaults
NONE
RMN
Request Current TV Wall
Format
NONE
SMN N1 N2
Set TV Wall N1 Row and
N2 Column
N1=1~15(Row),
N2=1~15(Column)
RBH
Request TV Wall Horizontal
Bezel Correction
NONE
SBH N1
Set TV Wall Horizontal
Bezel Correction
N1=0~255
RBV
Request TV Wall Vertical
Bezel Correction
NONE