5 – 170
© 2018 Cyphre Security Solutions, LLC.
5.10 Command: chassis
status
Displays information regarding the high-level status of the system chassis and main
power subsystem.
poh
This command will return the Power-On Hours counter.
identify <interval>
Control the front panel identify light. Default interval is 15 seconds. Use 0 to
turn off. Use "force" to turn on indefinitely.
restart_cause
Query the chassis for the cause of the last system restart.
selftest
Check on the basic health of the BMC by executing the Get Self Test results command
and report the results.
policy
Set the chassis power policy in the event of power failure.
list
Return supported policies.
always-on
Turn on when power is restored.
previous
Returned to previous state when power is restored.
always-off
Stay off after power is restored.
power
Performs a chassis control command to view and change the power state.
status
Show current chassis power status.
on
Power up chassis.
off
Confidential
BT1 Security Appliance User Guide
5 About the IPMITool