CY7C67200
Document #: 38-08014 Rev. *G
Page 27 of 78
Host n SOF/EOP Count Register [R/W]
• Host 1 SOF/EOP Count Register 0xC092
• Host 2 SOF/EOP Count Register 0xC0B2
Figure 27. Host n SOF/EOP Count Register
Register Description
The Host n SOF/EOP Count register contains the SOF/EOP
Count Value that is loaded into the SOF/EOP counter. This
value is loaded each time the SOF/EOP counter counts down
to zero. The default value set in this register at power-up is
0x2EE0, which will generate a 1-ms time frame. The
SOF/EOP counter is a down counter decremented at a
12-MHz rate. When this register is read, the value returned is
the programmed SOF/EOP count value.
Count
(Bits [13:0])
The Count field sets the SOF/EOP counter duration.
Reserved
All reserved bits must be written as ‘0’.
Host n SOF/EOP Counter Register [R]
• Host 1 SOF/EOP Counter Register 0xC094
• Host 2 SOF/EOP Counter Register 0xC0B4
Figure 28. Host n SOF/EOP Counter Register
Register Description
The Host n SOF/EOP Counter register contains the current
value of the SOF/EOP down counter. This value can be used
to determine the time remaining in the current frame.
Counter
(Bits [13:0])
The Counter field contains the current value of the SOF/EOP
down counter.
Bit #
15
14
13
12
11
10
9
8
Field
Reserved
Count...
Read/Write
-
-
R/W
R/W
R/W
R/W
R/W
R/W
Default
0
0
1
0
1
1
1
0
Bit #
7
6
5
4
3
2
1
0
Field
...Count
Read/Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Default
1
1
1
0
0
0
0
0
Bit #
15
14
13
12
11
10
9
8
Field
Reserved
Counter...
Read/Write
-
-
R
R
R
R
R
R
Default
X
X
X
X
X
X
X
X
Bit #
7
6
5
4
3
2
1
0
Field
...Counter
Read/Write
R
R
R
R
R
R
R
R
Default
X
X
X
X
X
X
X
X
[+] Feedback