background image

 3. Field Installation Checklist

 

 

 The Base Unit and access control panel have a common ground. 

 

 

 The top of the Base Unit (where antenna is located) points toward the sky. 

 

 

 For maximum range, Base Unit is installed approximately 10’ above ground (outdoors) or 5-6’ above floor  

               (indoors) 
   

  For maximum range, there is a direct line of sight between the Handheld Reader and Base Unit   

                (if there is no direct line of sight, a Repeater unit is recommended). 

   

  In applications with obstacles present (vehicles, trains, buildings, trees, etc.), the Base Unit is 

                mounted high enough to avoid interference.

 

 

      

   

  Metal mounting surfaces are not recommended for the Base Unit. If use of a metal surface is  

                unavoidable, Base Unit is spaced as far from metal surface as possible using non-metal spacer.  
   

 

For additional information, see Product Manual. 

 

Typical Handheld Reader Kit Wiring Connections 

11/2/2016                                           Complete documentation PDFs at 

CypressIntegration.com

 

*

Board B

Access 

Control  

Panel

DC

Power 

Supply

+8 to +16 Vdc
Ground

EXP(+)
EXP(-)

LED  In

D1/Data Out
D0/Clock Out

R1 IN 

Board A

RLY4 N.O.

RLY4 Com

RLY4 N.C.

RLY3 N.O.

RLY3 Com

RLY3 N.C.

RS232 Out

RS232 In

Ground

Aux Out

Relay2 Input
Relay1 Input

485(+)
485(-)
+5 Vdc Out
Prog Res 2
Prog Res 1
LED Input
D1/Data 
D0/Clock Out

8 to 16 Vdc In 
Ground

Board Sizes are not to scale

Reviews: