3. Field Installation Checklist
☐
The Base Unit and access control panel have a common ground.
☐
The top of the Base Unit (where antenna is located) points toward the sky.
☐
For maximum range, Base Unit is installed approximately 10’ above ground (outdoors) or 5-6’ above floor
(indoors)
☐
For maximum range, there is a direct line of sight between the Handheld Reader and Base Unit
(if there is no direct line of sight, a Repeater unit is recommended).
☐
In applications with obstacles present (vehicles, trains, buildings, trees, etc.), the Base Unit is
mounted high enough to avoid interference.
☐
Metal mounting surfaces are not recommended for the Base Unit. If use of a metal surface is
unavoidable, Base Unit is spaced as far from metal surface as possible using non-metal spacer.
For additional information, see Product Manual.
Typical Handheld Reader Kit Wiring Connections
11/2/2016 Complete documentation PDFs at
CypressIntegration.com
*
Board B
Access
Control
Panel
DC
Power
Supply
+8 to +16 Vdc
Ground
EXP(+)
EXP(-)
LED In
D1/Data Out
D0/Clock Out
R1 IN
Board A
RLY4 N.O.
RLY4 Com
RLY4 N.C.
RLY3 N.O.
RLY3 Com
RLY3 N.C.
RS232 Out
RS232 In
Ground
Aux Out
Relay2 Input
Relay1 Input
485(+)
485(-)
+5 Vdc Out
Prog Res 2
Prog Res 1
LED Input
D1/Data
D0/Clock Out
8 to 16 Vdc In
Ground
Board Sizes are not to scale