Away, Night, Day or Vacation mode. The Alarm History is played
automatically after signing in during an alarm.
Event Log (3,3)
Comfort keeps a record of the last 250 events (125 for FS17) related to
security functions e.g. arming, disarming, sign-ins, alarms. It keeps the
Date and Time of each event for easy traceability.
The Event Log will be announced over the phone in the format
(Date), (Time), (event)
January 24, 11:53 PM Intruder Alarm
If any key other than 1,2,3,4,9,0 is pressed, the voice menu will say
Press 1 for next
2 for previous
3 for Next Day
4 for Previous Day
0 for 1st
9 for last
Pressing 1,2,3,4,9, or 0 during the event log announcement will
immediately interrupt the announcement and go to the specified event.
In this way, you can go quickly to the event of interest
The events which are reported in the Event Log are:
Dial-out to Monitoring Station failed (Busy, no answer, no
acknowledgment, no kissoff)
N/A
Dial Failure
SEM, Door Station or Keypad tamper, 33-35=SEM 1-3, 49-51=Door
Station 1-3 and 65-72=Keyad1-8
Restore
33,49,65 Tamper Alarm
The system is armed to Day Mode
N/A
Day Mode
Keypad 1-8 data failure. Prefix denotes ID 65=Keypad 1,
66=Keypad 2, 67=Keypad 3, 68=Keypad 4
65 Restore
65 Communications
Failure
Door Station 1-3 Data Failure. Prefix denotes ID. 49=Door Station 1,
50=Door Station 2, 51=Door Station 3, 52=Door Station 4
49 Restore
49 Communications
Failure
Slave Expansion Module 1-3 Data Failure. Prefix denotes
iD.Address 33=SEM 1, 34= SEM 2, 35= SEM 3
33 Restore
33 Communications
Failure
Date or Time Changed
N/A
Change Time
A zone was bypassed
Zone No.
Bypass Off
Zone ‘Name’ Bypass
The battery was tested with AC ‘OFF’ and found to be low
Restore
Battery Warning
System armed to Away Mode - Full Set
N/A
Away Mode
System failed to arm, returned to Security Off Mode.
N/A
Arm Failure
Dial-out acknowledged by recipient pressing # key.
N/A
Alarm Message OK
Alarm activation aborted within the ‘Abort Time’.
N/A
Alarm Erased
Description
Restoral
Voice Event
Comfort II User Manual
69