Microphone  ON for Recording or Intercom

Steady

Mic (Red)

the message is for. Sign in with user code to hear
the message

Installation

KP04/KP05 should be installed in an indoor location, not

outside the premises for security reasons.

y

Remove the screw at the base and pull the front

housing from the back housing.

y

Mount the back housing on the wall using the

screws supplied. KP04/KP05 can replace KP01/02.

y

Connect the 6 wires from the terminal blocks (JP1,

JP2 , JP3) to the Comfort PCB according to the

signal name. Note the 12V should be connected to

the 12V terminal on Comfort, not S12V 

y

When replacing an existing KP01/KP02, note that

the pairs of wires KA/KB, 12V/COM, Mic/Voice are

reversed on the connectors. 

y

If more than one Keypad/Door Station is used,

connect their 12V and ground wires back to

Comfort  individually, not in series to avoid

excessive  voltage drop along the cable. 

y

Set ID shunts for each of the  keypads (SW1).

They must be numbered consecutively, i.e. ID 1,

followed by ID 2 for 2nd KP.

y

Set the correct number of Keypads using

Comfigurator (or using the keypad Location 1675).

The default is 1. Reset Comfort after changing the

value.

Comfort II Text Synchronisation 

If the LCD displays “Wrong Text. Press *1 to sync”.

press and hold the “*” followed by “1” keys to  sync the

KP04 text with the Comfort vocabulary,. The screen

shows to “Downloading” with the downloading status

bar. After the process completes, the keypad will reset

and there will be a “beep” heard.

Revised November 2012