PS-28 Cruiser
PS-28N Cruiser
CR-MM-1-0-00
CHAPTER 12 – INSTRUMENTS AND AVIONICS
Revision No.: 11
Date of issue: 2014-10-29
12 - 50
WARNING:
WHEN CONNECTING THE PITOT-STATIC SYSTEM HOSES PAY
INCREASED ATTENTION. THERE MUST NOT BE ANY INCORRECT
CONNECTION! CONNECT THE HOSE MARKED S LETTER TO THE
PORTS MARKED BY STATIC AND THE HOSE MARKED T LETTER TO
THE PORT MARKED BY PITOT.
NOTE:
The hose for static pressure line mark by
S
letter and for total pressure mark
by
T
letter.
(f) Connect the connectors (2, 3) to the ADAHRS module.
(g) Install the covers on the bottom of the fuselage rear part.
(h) Set the
MASTER BAT
,
EFIS1 / EFIS 2
switches to ON and do operational test of the
system.
1 SV-ADAHRS-200 module
9 Nut (4 pcs.)
2 SkyView network connector
10 Washer (4 pcs.)
3 OAT probe connector
11 SV-OAT-340 probe
4 Pitot port
12 Nut
5 Static port
13 Washer
6 Hose
For information:
7 Hose clip
14 Bracket
8 Screw (4 pcs.)
15 Fuselage skin
Fig. 12-41
: SV-ADAHRS-200 module and SV-OAT-340 probe removal / installation