PS-28 Cruiser
PS-28N Cruiser
CR-MM-1-0-00
CHAPTER 12 – INSTRUMENTS AND AVIONICS
Revision No.: 23
Date of issue: 2020-01-15
12 - 68
Elevator trim calibration
1. With a cursor, select an option ELEV CALIBRATION.
2. Press button 8 RECAL.
3. Set the elevator trim tab to the max. lowest position (FULL DOWN).
4. Press button 8 SET.
5. Set the elevator trim tab to the max. upper position (FULL UP).
6. Press button 8 SET.
7. Set the elevator trim tab to the center position (TAKE-OFF).
8. Press button 8 DONE to complete the calibration procedure.
Flaps calibration
1. With a cursor, select an option FLAPS CALIBRATION.
2. Press button 8 RECAL.
3. Set the flaps to the 0° - max. upper position (FLAP STOP 1).
4. With a cursor, fill in a value for flaps settings to 0° +00.
5. Press button 8 SET.
6. Set the flaps to the 12° - take-off position (FLAP STOP 2).
NOTE:
To set flaps to the 12° angle, use appropriate protractor.
7. With a cursor, fill in a value for flaps settings to 12° +12.
8. Press button 8 SET.
9. Set the flaps to the 30° - max. lowest position (FLAP STOP 3).
10. With a cursor, fill in a value for flaps settings to 30° +30.
11. Press button 8 SET.
12. Press button 7 DONE to complete the filling procedure of the values for flaps settings.
13. Press button 8 DONE to complete the calibration procedure.
Fuel sensors calibration
1. Drain all fuel from both fuel tanks (see Chapter 9.5.2).
2. With a cursor, select an option FUEL TANK 1 (LEFT) CALIBRATION.
3. Press button 8 RECAL.
4. With a cursor, fill in a value for total volume of the fuel tank. 57 liters 057.
5. Press button 8 NEXT.
6. Check whether the left tank is empty.
7. Press button 8 START.
8. To the left tank add exactly 5 liters of fuel.
9. Let the fuel level to stabilize.
10. Press button 8 ADD.
11. Check the value in the upper right corner of the screen TOTAL LITERS ADDED for the
total amount of added fuel.