background image

1

6

 

LCD SCREEN

 

The LCD is an easy to use screen that gives the owner / installer information regarding programming and 
motor status. Whenever the motor is programmed or a fault occurs, refer to the screen for diagnostic assis­ 
tance. In certain cases the screen will give a message that reads “Call Technician’ this means that  the motor 
needs to be checked by an installer. The messages on the screen are generally self explanatory. However 
the following table gives a description of the messages and their meaning.

 

MESSAGE 

MEANING / ACTION

 

LOW BATTERY 

THIS MESSAGE WILL SHOW AFTER INITIAL START UP, IF 
THE LOW BATTERY MESSAGE REMAINS AFTER THE 
MOTOR IS TRIGGERED :­ 
CHECK BATTERY VOLTAGE / CHECK CHARGER VOLTAGE 

MAINS FAIL 

CHECK THE MAINS POWER / CHECK TRANSFORMER / 
CHECK CHARGER. 

GATE CLOSED 

THE GATE IS IN THE CLOSED POSITION. 

GATE OPEN 

THE GATE IS IN THE OPEN POSITION. 

OBSTRUCTION 

THE GATE HAS SENSED AN OBSTRUCTION. CHECK THE 
WHEELS / ROLLERS/ RACK/ BRACKETS/ FUSES/ FORCE 
SETTING POTS. 

AUTO­CLOSE ACTIVE 

THE GATE IS SET TO AUTO CLOSE. 

PARTY MODE 

THE GATE IS IN AUTO­CLOSE OVERRIDE . 

PROGRAM MODE 

THE GATE IS IN PROGRAM MODE. 

PROGRAMMING CLOSE POSTION 

THE GATE IS CLOSING WHILE PROGRAMMING. 

MARKER OK 

THIS MESSAGE WILL SHOW WHEN THE MAGNET PASSES 
THE MARKER. THIS INDICATES THAT THE MARKER IS IN 
WORKING ORDER. 

PROGRAMMING OPEN POSITION 

THE GATE IS OPENING WHILE PROGRAMMING. 

PROGRAM COMPLETED 
REMOVE LINK 

THE PROGRAM IS COMPLETE. REMOVE THE PROGRAM 
LINK. 

SERVICE DUE 

THE MOTOR REQUIRES A SERVICE. 

NO REV PULSES 

FAULTY REV COUNTER, PC BOARD MOUNTING MAY BE 
LOOSE, MAGNET HOLDER BROKEN. 

BEAMS BLOCKED 

THE INFRA­RED SAFETY BEAMS ARE BLOCKED / FAULTY/ 
THE BEAMS LINK HAS BEEN REMOVED. 

LCD SCREEN 

Some of the messages below have been shortened  to 
show the main message. Certain messages will also 
show the action needed.

Summary of Contents for CONDO

Page 1: ...P9 ANCHORING THE MOTOR P11 SECURING THE MOTOR P12 MOUNTING THE RACK P13 FILLING THE GEARBOX OIL P14 MOUNTING THE MAGNET P14 MAIN PC BOARD LAYOUT P15 LCD SCREEN P16 SETTING THE MOTOR DIRECTION P17 PROG...

Page 2: ...nding BMG Imports offer a Standard Warranty on this equipment The following terms and conditions apply to ALL warranty claims BMG Imports warrants the ORIGINAL purchaser at the point of sale that the...

Page 3: ...no circumstances may 220V AC be run using Communication cable Ripcord or Cabtyre BMG Imports will not be held liable for any accident incident resulting in damage injury or death ensuing from the inst...

Page 4: ...ckle charge to maintain 13 8 VDC charge to the battery Main PC board this is the printed circuit board that contains all the electronic components that oper ate the motor NOTE Always remove the power...

Page 5: ...5 MOTOR LAY OUT 4 HOLES TO PEG OR BOLT THE PLATE CONDUIT ENTRY HOLES FOUNDATION PLATE 12VOLT DC ELECTRIC MOTOR MAIN PC BOARD CABLE RISERS 12 VOLT BATTERY ACCESS DOOR WITH LOCK L C D SCREEN...

Page 6: ...to avoid any damage to the motor The rail must be level and should be above ground level this will assist with keeping debris out of the path of the wheels Any debris lying on the rail may cause the...

Page 7: ...assist with the smooth operation of the gate The gate must not move on its own when left in any position on the rail D A C E will not be held responsible for any gates bumping the ends stops when a ga...

Page 8: ...equired to start the gate rolling This is the start up force At no stage while moving the gate must the reading exceed the force shown in the table below START UP FORCE Start up force table Sprint max...

Page 9: ...MANUAL OVER RIDE PLACING MOTOR INTO MANUAL OVER RIDE Open the door as in step 1 above Turn the thumb wheel CLOCKWISE until the gate moves freely PLACING THE MOTOR IN NORMAL OPERATION MODE Turn the th...

Page 10: ...ter proof conduit and must be terminated inside the motor There must be no joins in the cable underground The cable should be a two core 1 5mm cable DO NOT USE COMMUNICATION CABLE AS THIS WILL VOID AN...

Page 11: ...e The concrete should be allowed sufficient time to set before the mo tor is mounted onto the plate Allow concrete to set and then place the foundation plate onto the concrete plinth 3 Foundation plat...

Page 12: ...bove the flood level or if this is not possible a flood proof wall should be constructed around the motor After placing the motor onto the three jack up bolts place the three clamping nuts and washers...

Page 13: ...B Step 4 push the gate towards the open position continuing to secure the rack to the full length of the gate Ensure that the rack is securely meshed with the pinion at all times during this operatio...

Page 14: ...ses the motor must not exceed 3mm To check this manually move the gate until the magnet is directly over the pinion gear then measure be tween the magnet and the motor lid If the gap is more than 3mm...

Page 15: ...according to the instructions in this manual It is very important to remember to disconnect ALL power before connecting or discon necting any wiring MAIN P C BOARD LAY OUT LED extension con nector Re...

Page 16: ...THE CLOSED POSITION GATE OPEN THE GATE IS IN THE OPEN POSITION OBSTRUCTION THE GATE HAS SENSED AN OBSTRUCTION CHECK THE WHEELS ROLLERS RACK BRACKETS FUSES FORCE SETTING POTS AUTO CLOSE ACTIVE THE GAT...

Page 17: ...The motor wires are the two wires that extend from the electric motor and are connected to the main PC board The other reason that the setting of the motor direction is important is that the motor wi...

Page 18: ...is designed to assist with the programming of the motor Step 1 manually open the gate 1m 1 5m Step 2 engage the motor using the thumb wheel Step 3 have dip switch 1 2 in the ON position Step 4 apply t...

Page 19: ...afe storage It is recommended that the remotes are numbered in order of programming This will assist with erasing any lost or stolen remote at a later stage Step 1 place the jumper over the two pins o...

Page 20: ...OSE Auto close is an option that allows the gate to close automatically after a chosen time delay this delay can be from 10 to 70 seconds Auto close is selected by using the dipswitches on the main PC...

Page 21: ...1m Collision Sensing Electronic Electronic Duty Cycle 20 20 Motor Voltage 12 Volt 12 Volt Motor Power 120 watts 120 watts Opening Time 25m min 18m min Supply Voltage at Gate 16V AC 16V AC On board rec...

Reviews: